NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 681 pages

Chain of custody log, DOT materials, 1998

Machine-extracted title · confidence 52%

Codified records of documents and custody in DOT files.

NYC-WTC_000355074–000355754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pt. 37, App. A 49 CFR Subtitle A (10-1-98 Edition)

4.1.8 Accessible BaUdlegm Alteration_.

addition of elements. spaces. or features which (t0 A slope between 1:8 and 1:10 is are in full and strict compliance with the mini- allowed for a max imum rise of 3 inches. A mum requirements for new cnnstructlon and slope steeper than 1:8 is not allowed. which are necessary to provide accessibility. (bi Stairs: Full extension of handrails at (k) EXCEPTION: stairs shall not be required in alterations where such extensions would be hazardous or impos- (0 These guidelines do not require the sible due to plan configuration Installation of an elevator In an altered facility that is less than three stories or has less than (C) Elevators: 3.000 square feet per story unless the building is a shopping center, a shopping mall, the (0 If safety door edges are provided In professional office of a health care provider, or exdating automatic elevators. automatic door another type of facility as determined by the reopening devices may be omitted (see 4.10.6). Attorney General. fW where existing shaft configuration (11) The esanption provided in paragraph or technical Infeasibility prohibits strict com- (I) does not obviate or limit in any way the pliance with 4.10.9, the minimum car plan obligation to comply with the other accessibility dimensions may be reduced by the minimum requirements established In these guidelines. amount necessary, but in no case shall the For example. alterations to floors above or inside car area be smaller than 48 in by 48 In. below the ground floor must be accessible regardless of whether the altered facility has an (WI Equivalent facilitation may be pro- elevator. If a facility subject to the elevator vided with an elevator car of different dimen- exemption set forth In paragraph (0 nonethe- sions when usability can be demonstrated and less has a full passenger elevator, that elevator when all other elements required to be acces- shall meet, to the maximum extent feasible, the sible comply with the applicable provisions of accessibility requirements of these guidelines. 4.10. For example, an elevator of 47 In by 69 in (1195 mm by 1755 mm) with a door opening on (2) Alterations to an Area Containing a the narrow dimension, could accommodate the Primary Function: In addition to the require- standard wheelchair clearances shown In ments of 4.1.6(1), an alteration that affects or Figure 4. could affect the usability of or access to an area containing a primary function shall be made so (d) Doors: as to ensure that, to the maximum extent feasible, the path of travel to the altered area (0 Where it is technically infeasible to and the restrooms, telephones, and drinking comply with clear opening width requirements fountains serving the altered area. are readily of 4.13.5. a projection of 5/8 in maximum will accessible to and usable by individuals with be permitted for the latch side atop. disabilities, unless such alterations are dispro- portionate to the overall alterations In terms of (10 If existing thresholds are 3/4 In high cost and scope (as determined under criteria or less, and have (or are modified to have) a established by the Attorney General). beveled edge on each aide, they may remain.

(3) Special Technical Provisions for Alter- (e) Toilet Rooms. ations to Existing Buildings and Facilities: (0 Where it is technically infeasible to (a) Ramps: Curb ramps and Interior or comply with 4.22 or 4.23, the Installation of at exterior ramps to be constructed on sites or least one unisex toilet/bathroom per floor. in existing buildings or facilities where space located in the same area as exdattng toilet limitations prohibit the use of a 1:12 slope or facilities, will be permitted In Ueu of modifying less may have slopes and rises as follows: existing toilet facilities to be accessible. Each unisex toilet room shall contain one water (0 A slope between 1:10 and 1:12 is closet complying with 4.18 and one lavatory allowed for a maximum rise of 6 inches. complying with 4.19, and the door shall have a privacy latch.

12

390

NYC-WTC 000355473

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000355473Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →