NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 414 pages

Ground Zero environmental health schools report

Machine-extracted title · confidence 45%

Document discussing lessons learned in children's environmental health related to Ground Zero sites.

NYC-WTC_000276036–000276449
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

CHAPTER II REGULATIONS OF THE COMMISSIONER § 155.7

(ii) Enclosed courts of more than a 700-square foot area shall have at least two exits, remote from each other, equipped with hardware of a type which will always permit the door to be opened from the court side without the use of a key. (9) Hardware, (i) All door hardware from spaces of pupil occupancy shall be of a type that will always permit the door to be opened from within the space without the use of a key. (ii) All exterior and interior doors in exitways, and exit doors from places of assembly shall have panic hardware, except that panic hardware is not required for push/pull interior exit doors if these doors have nonlatching hardware. Panic hardware shall not be required for exterior corridor doors serving less than three classrooms or for doors serving only service areas such as boiler room, kitchen or storerooms. (iii) Exit doors shall not be locked or chained or otherwise rendered inoperable from the inside at any time. (b) Smoke and fire control. As used in this subdivision, the terms Class “A”, “B” or “C” refer to types of construction which are defined by subdivision 11 of section 11 of the Local Finance Law. (1) In Class “B” and Class “C" buildings of two stories or more, unless otherwise ap­ proved, stairs shall be enclosed at each floor level and every floor shall be separated from levels above and below by stair enclosures and/or smoke banders constructed to obstruct effectively the passage of smoke and fumes, or every space of pupil occupancy shall be provided with direct exit to the exterior. In appropriate instances, alternate means of egress may be required and stairway enclosures in Class “A” construction may be required. (2) Class “B” and Class “C” buildings shall not have places of assembly above the first floor, except in a Class “B” building a written exception may be granted where it is determined by the commissioner that adequate exits exist, (3) In appropriate instances, doors, walls and ceilings of places of assembly and exitways (corridors, stairs, vestibules, etc.) may be required to be finished with fire retardant materials or coatings. (4) Stairway enclosures required by paragraph (1) of this subdivision and smoke barriers required by paragraph (5) of subdivision (a) of this section shall be constructed of noncombus­ tible materials of such design and detail to obstruct effectively the passage of smoke and fumes. (i) Doors in stair enclosures and smoke barriers shall be metal, metal covered, approved treated wood construction, or solid bonded core wood doors not less than l’A inches thick. (ii) Glazing in doors, sidelights and frames shall be one-quarter inch wire glass. (iii) Such doors shall swing in the direction of egress, with no latching or locking devices unless operated by panic hardware. Double-acting hinged doors are not permitted and corridor pockets opposing swing of doors shall conform to the provisions of paragraph (2) of subdivision (a) of this section. (iv) Such doors shall be self-closing and maintained in a normally closed position unless approved automatic release devices are provided, whereby upon interruption of an electrical circuit, the door is released and becomes self-closing. Ilie electrical circuit shall be posi­ tively interrupted by operation of an approved smoke detection system and/or activation of the building fire alarm system. Fusible links shall not be used to hold open such doors. (5) Wood floors shall not be treated or finished with oil. Floors so finished previously shall be cleaned and refinished with a penetrating seal. (6) Fire extinguishers shall be located so that no point in a corridor, lobby or stair is more than 120 feet from an extinguisher. Fire extinguishers shall also be placed readily accessible to audtorium stages, shops, cafeterias and kitchens, boiler rooms, science labs and accessible from other places which are possible sources of fire. Fire extinguishers shall bear the Under­ writer’s label and be of a type most suitable for the kind of fire most likely to occur in a given area. (7) Fire-resistive (hourly rated) floors, interior walls and doors, and ceilings shall be provided at the following spaces unless otherwise approved by the commissioner. Those spaces

9-30-99 699 Education

CITY_21MC100_012173206

NYC-WTC_000276361

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276361Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →