NYC 9/11 Public Portal Document

} 155.7 TITLES EDUCATION

having a roof over the entire space may have roof construction and ceilings of nonrated fire- resistive materials. (i) Two-hour fire-rated construction with I'/i hour fire-rated, self-closing fire doors are required at: (a) boiler, heater or furnace rooms; (b) refrigeration, electrical and equipment rooms; (c) incinerator rooms; (d) storerooms for fuel, flammable liquids and gas powered equipment; and (e) transformer vaults. (ii) Required fire doors shall be maintained in a normally closed position and not held open by fusible links. (iii) Combustible attic space shall not be used for storage. (c) Accident protection. (1) Glazing of panels and doors shall be with safety glazing materials as follows, unless glazed areas are protected by approved grilles or rails; (i) interior exit doors, exterior exit doors and immediately adjacent sidelights, except where glazing is 48 inches or more above the floor; (ii) all glazed panels where glazing is within 18 inches of the floor, or platform level of music-room type risers; (iii) gymnasiums and playrooms and elsewhere where subject to physical abuse; (iv) acceptable safety glazing materials shall be at least one-quarter inch thick wire glass, one-quarter inch tempered (heat treated) glass, one-quarter inch laminated safety glass, or approved plastic materials. (2) Glazed doors and sidelights within six feet of such doors shall be marked by appropri­ ate means in accord with the provisions of Part 47 of Title 12 of the Official Compilation of Codes, Rules and Regulations of the State of New York, except marking on door and/or sidelight is not required: (i) where less than 80 percent of the area of the door or sidelight above a reference line 18 inches above the floor is glazed; (ii) where width of sidelight is not more than 20 inches, with 1 3/4 inch minimum opaque stiles; (iii) where floor treatment a distance of three feet out from a sidelight will deter approach; (iv) where sidelights are supported on 18-inch minimum height opaque sill and wall construction; (v) where sidelights are protected by approved 18-inch minimum height permanent barriers such as benches, planters or guardrails, extending across at least two thirds of the sidelight. (3) Window cleaning. Safety provisions shall be made for persons engaged in window cleaning. Windows shall be cleaned from approved safe surfaces, windowsills or ledges, boatswain’s chairs or scaffolds, all as defined in Part 21 of Title 12 of the Official Compilation of Codes, Rules and Regulations of the State of New York. (i) A safe surface is a place where the cleaner is working not over six feet off the floor or grade and not over three feet above a stair run. Ladders may be used generally when the top of the window is not over 35 feet above grade or floor. Windowsills and ledges may be used when the window openings are provided with approved anchors for use with safety belts. Approved boatswain’s chairs and scaffolds also may be used. (d) Mechanical. Mechanical equipment, heat-producing and cooling equipment, auxiliary apparatus and controls, and installation and use of same, shall be such as will insure safe operation

700 Education 9-30-99

CITY_21MC100_012173207

NYC-WTC_000276362

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276362Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →