§ 155.7 TITLES EDUCATION

(2) Dead-end corridor pockets shall not exceed a maximum depth of 1 ‘/ztimes the width of the pocket or 116 times the width of the corridor, whichever is less, unless otherwise approved by the commissioner. (3) Corridors and exitways shall be kept clear and free of obstructions at all times. (4) Fixed and portable security gates shall not be located or used where they will obstruct exits or create dead-end conditions for occupied spaces. (5) Every space of pupil occupancy over 500 square feet in area shall have two separate means of egress from such space. A space of pupil occupancy is any room or self-contained space housing pupils on a regular basis, other than a place of assembly or small rooms where no more than 10 pupils are under direct, responsible, adult supervision. Each means of egress shall be in a separate smoke zone, unless Immediately adjacent to an approved exit. The primary exit is commonly the opening to the corridor. The second means of egress may be a door opening into a separate smoke zone, or a door directly to the exterior, or a window of such size and design that will facilitate egress, or a door providing egress through adjacent spaces where specifically approved. (i) Any point in a space of pupil occupancy shall not exceed a maximum of 50 feet straight-line distance to an exit, unless otherwise approved by the commissioner. Any additional exit necessary to satisfy this requirement shall be remote and may be required to be directly to the exterior. (ii) When spaces of pupil occupancy are defined in an open area by wardrobes, cabine­ try and other furniture which does not present obstructions to egress and which allows students to circulate freely from one space to another, the total open space is considered, for exiting purposes, as a single space. Exits from such open-planned space shall meet require­ ments determined by the commissioner. (6) Required emergency, egress windows shall be of a size and design, including hardware and, in appropriate instances, steps or ladder to high sills, that will permit and facilitate emergency egress. Such windows shall be free of obstructing screens or storm sash. (i) The minimum clear opening area for such windows shall be six square feet, with a minimum dimension of 24 inches, unless otherwise approved by the commissioner, (ii) At least one such window in each space of pupil occupancy shall be marked with an appropriate sign identifying it as an emergency egress window. (7) Places of assembly. A place of assembly is any area used for the assembly of 100 or more persons, and spaces over 1800 square feet in area used for the assembling of persons. A place of assembly shall have at least two exits remote from each other. (i) Maximum occupancy for places of assembly shall be based on the number and size of existing approved exits on the basis of 50 persons for each one-half exit unit of 11 inches. Where existing exits are inadequate for the occupancy capacity of a place of assembly, or when directed by the commissioner, signs restricting the number of occupants shall be conspicuously posted at each exit location. Signs shall read in red letters on white back­ ground:

“MAXIMUM OCCUPANCY —3" high, 3/4" stroke

NOT TO EXCEED —2" high, 1/2" stroke

XXX PERSONS” —3" high, 3/4" stroke (8) Courtyards with completely enclosed perimeters are areas of possible pupil occupancy and must be provided with exits as a space of pupil occupancy and as follows, unless otherwise approved by the commissioner: (i) Enclosed courts up to a700-square foot area shall have at least one exit equipped with hardware of a type which will always permit the door to be opened from the court side without the use of a key.

698 Education 9-30-99

CITY_21MC100_012173205

NYC-WTC_000276360

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276360Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →