NYC-WTC_000143746
Letter summarizing real estate industry comments on draft EPA guidance for building air protection environments.
1 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗Department of Buildings report containing findings and recommendations regarding the World Trade Center site.
NYC-WTC_000166488–000166533Folder label: “NYC DOB WTC Building Code Task Force Findings and Recomendations - Feb. 2003”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document ■!
4.2.1 Capacity and Location of Stairwells
In most areas related to egress capacity, further information and empirical investigation is required to warrant introduction of new. standards into the code. Despite having limited empirical I and modeling documentation, further evidence of a need for stair capacity increase on lower i floors would have to be provided to make a specific recommendation. The Task Force looks to NIST for a fnore comprehensive study of this issue. However, the goal of increased capacity, in absence of new workable design criteria could be addressed immediately with a change in the ( way developed space is calculated. To encourage the inclusion of more stairwells or wider stairwells in buildings, the Task Force recommends that the floor area of stairwells above the minimum requirements be excluded from total Floor Area, in the calculation of a building's potential maximum developable floor area. This recommendation would require a change in the Zoning Resolution.including environmental review and City Planning Commission Approval. Remote location of stairwells was also a concern to the Task Force, given the Building Performance Study conclusions. Currently, number and size of stairways, as well as remote location, are dictated by occupant load, determined by floor size and travel distance. The logic behind separating stairwells and placing them at a prescribed distance is predicated on redundancy (a lesson learned from many building tragedies), given the possibility of a catastrophic event isolating a portion of a floor. A building core organizes circulation, mechanical services, plumbing and power utilities, allowing for the necessary efficiency of an office floor "plate". Design of a building's core is not generic, but highly specific to a building, and thus, stair 1 quantity and location should be evaluated for the idiosyncrasies of individual building design and I risk profile. In reality, high-rise building design depends on this type of core construction. The Task Force believes that this issue should be examined by NIST. I I An additional building design efficiency includes the use of scissors stairs, two stairwells that adjoin one another and share a common shaft, but are separately enclosed. Such stairs are little used except in buildings with small floor plates, but allowable by the current code. The Task Force recommends that this design be limited to high-rise commercial buildings with a floor plate square footage under 10,000 square feet. I Recommendation 1
4. Work with the Department of City Planning to exempt floor, area of stairwells above minimum requirements from zoning Floor Area Ratio I I (FAR) calculations to encourage the inclusion of more stairwells or wider stairwells in buildings.
5. Prohibit the use of scissors stairs in high-rise commercial buildings with a floor plate of over 10,000 square feet.
I ' 4.2.2 Clarity of Egress Pathway The clarity or "readability" of the egress path is essential for a successful evacuation. When fire or another threatening condition impedes sensory perception, decision making for evacuees should be facilitated by systems that offer heightened comprehensibility. The Working Group concluded that improvements to the marking of the egress path, doors and stairs be implemented and that I existing buildings' exit signs should be retrofitted with either battery or generator backup power. It also concluded that overall lighting level was sufficient and that color coding stairwells could confuse the current requisite identification scheme.
Page 20 WTC Building Code Task Force February 2003 Findings and Recommendations
NYC-WTC_000166506
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000143746
Letter summarizing real estate industry comments on draft EPA guidance for building air protection environments.
1 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141695
Section of an environmental assessment describing existing physical conditions and construction impacts at the World Trade Center site.
4 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164903
Forwarded programmatic agreement documentation addressing post-disaster building cleaning procedures and eligible building list for recovery efforts.
2 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141585
Map showing the condition of buildings at the World Trade Center site as of September 21, 2001.
9 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164098
Distribution of materials provided at January 15, 2002 WTC contractor health and safety meeting.
4 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093788
Fax transmittal from the Mayor's Office regarding a March 2002 meeting with the building group.
2 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000168718
Document outlining fire evacuation procedures and objectives for 7 World Trade Center.
3 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150931
Cover fax from the Mayor's Office forwarding DEP documents regarding exterior clean-up to be reviewed before a meeting with building owners.
2 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173475
Letter providing comments on submitted architectural plans for the Mayor's Office of Emergency Management.
2 shared non-person entities · 1 shared topics · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153468
Page containing illegible text and a document identifier for the EPA Inspector General series.
6 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165271
Engineering drawings and specifications for replacing a high-pressure water line under the Lincoln Tunnel contract.
1 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000143354
Fragmented text containing only a reference number and unreadable characters from the DEP Box 06 collection.
7 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Cited alongside this record in an Ask answer
NYC-WTC_000095781
Part III of a permit application dated January 10, 2006 regarding health and safety for remediation at 30 West Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
Archival folder label from the Office of the Mayor for World Trade Center records, identified as Folder 0139.
Cited alongside this record in an Ask answer