ce Of the Secretary of Transportation Pt. 37, App. A

4.1.7 Aecesslbis B uildlog1 18lstode Prese>natdon

(I Where a is technically infeasible to through 4.35 and the applicable special appli- required standard stall (Fig. 30(a)). or cation sections 5 through 10 unless it is deter- tnstaua wt other codes prohibit reduction of the mined in accordance with the procedures in durecount (Le.. removal of a water closet in 4.1.7(2) that compliance with the requirements double-wide stall). either for accessible routes (exterior and Interior). order to create a ramps. entrants or toilets would threaten or alternate stall (P1g.30(bl) may be provided in standard stall. destroy the historic signadcance of the building lieu of the or facility In which case the alternative require- (till When wasting toilet or bathing ments in 4.1.7(3) may be used for the feature. fad are being altered and are not made signage complying with 4.30.1. FXCFFI'ION: (Reserved). sccesstble, 4.30.2. 4.30.3.4.30.5. and 4.30.7 shall be provided indicating the location of the nearest (b) Dd)nalon. A qualified historic building am ble toilet or bathing facility within the or facility is a building or facility that is facility. (U Listed in or eligible for listing in the (U Assembly Areas: National Register of Historic Places: or

(U Where it is technically infeasible to (W Designated as historic under an disperse accessible seating throughout an appropriate State or local law. altered assembly area, accessible seating areas may be clustered. Each accessible seating area (2) Procedures: shall have provisions for companion seating and shall be located on an accessible route that (a) Alterations to Qualified Historic Build- also serves as a means of emergency egress. ings and Facilities Subject to Section 106 of the National Historic Preservation Act (II) Where It is technically infeasible to alter all performing areas to be on an accessible (U Section 106 Process. Section 106 of route, at least one of each type of performing the National Historic Preservation Act (16 area shall be made accessible. U.S.C. 470 0 requires that a Federal agency with jurisdiction over a Federal. federally (g) Platform Lifts (Wheelchair Lifts): In assisted, or federally licensed under alcing alterations, platform lifts (wheelchair lifts) consider the effects of the agency's undertaking complying with 4.11 and applicable state or on buildings and facilities listed in or eligible local codes may be used as part of an acces- for listing in the National Register of Historic sible route. The use of lifts is not limited to the Places and give the Advisory Council on His- four conditions In exception 4 of 4.1.3(5). toric Preservation a reasonable opportunity to comment on the undertaking prior to approval (h) Dressing Rooms: In alterations where of the undertaking. technical infeasibility can be demonstrated, one dressing room for each sex on each level shall (1) ADA Application. Where alterations be made accessible. Where only unisex dress- are undertaken to a qualified historic building ing rooms are provided, accessible unisex or facility that is subject to section 106 of the dressing rooms may be used to fulfill this National Historic Preservation Act. the Federal requirement. agency with jurisdiction over the undertaking shall follow the section 106 process. If the 4.1.7 Accessible Buildtiags: 13lstorte State Historic Preservation Officer or Advisory Presmvatlon. Council on Historic Preservation agrees that compliance with the requirements for acces- (1) Applicability: sible routes (exterior and interior). tamps. entrances, or toilets would threaten or destroy (a) General Rule. Alterations to a qualified the historic significance of the building or historic building or facility shall comply with facility, the alternative requirements in 4.1.6 Accessible Buildings: Alterations, the 4.1.7(3) may be used for the feature. applicable technical specifications of 4.2

13

391

NYC-WTC 000355474

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000355474Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →