Indoor air quality field report, BOE school

Machine-extracted title · confidence 40%

March 26, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.

NYC-WTC_000295923–000295927
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr Bernard P Orlan March 27 2002 Indoor Au- Quality Assessment Page 4 H S for Leadership & Public Service (M894) ATCProiectNo 15 19125 0290 concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter Three (3) of the twelve (12) instantaneous outdoor measurements were above the USEPA recommended concentration of 40 pg/m3 for sensitive individuals such as asthmatic people and children

* The measurements made during this assessment were instantaneous readings the NPAAQS is a 24 hour average

TVOC Concentration

The TVOCs concentrations were 0 ppm inside the building These concentrations were below the AIHA guidelme for odor control of 1 ppm The outdoor TVOC concentration was also 0 ppm

OBSERVATIONS

During this assessment ATC noted the following • The interior of the building appeared clean and free of dust and debns • The building was occupied at the time of the assessment • No smoke odor was detected in the building

FINDINGS

Based on the real time measurements the following findings are presented

1 Concentrations of CO and TVOCs were below applicable standards and guidelines 2 One hundred and one (101) indoor measurements for temperature were above and twenty seven (27) measurement were within the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55 1992 dunng the heating season (wintertime conditions) 3 One hundred and twenty one (121) of the indoor measurements for relative humidity were below and seven (7) measurements were within the ASHRAE recommended range of 30 to 60 percent for occupant comfort 4 One (1) of the mdoor measurements for CO2 was above the ASHRAE Standard 62 1999 recommended maximum concentration of <700 ppm above the background level The highest measurement was taken in the gymnasium at 12 54 PM with one (1) occupant Levels above the recommended maximum do not indicate a health nsk Carbon dioxide measurements are used as an indicator of available outdoor air The pnmary source of CO2 indoors is occupant respiration 5 All of the indoor measurements for PM2 5 were below the NPAAQS of 65 pg/m^ 24 hour average concentration of particulate matter 2 5 micrometers or less m aerodynamic diameter and the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children One (1) of the outdoor measurements for PM2 5 was above the NPAAQS of 65 pg/m3 24 hour average concentration of particulate matter 2 5 micrometers or less m aerodynamic diameter Three (3) of the twelve (12) instantaneous outdoor measurements were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children

CITY_21MC100_003085610

NYC-WTC_000295926

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000295926Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →