Mr Bernard P Orlan March 14 2002 Indoor Air Quality Assessment Page 4 H S for Leadership & Public Service fM894) ATCProiectNo 15 19125 0290 above and one (1) was below the USEPA recommended concentration for sensitive individuals such as asthmatic people and children of 40 pg/m^

* The measurements made durmg this assessment were instantaneous readings the NPAAQS is a 24 hour average

Type Concentration

The TVOCs concentrations were 0 ppm mside the building These concentrations were below the AJHA guideline for odor control of 1 ppm The outdoor TVOC concentration was also 0 ppm

OBSERVATIONS

During this assessment ATC noted the following • The interior of the building appeared clean and free of dust and debris • The building was occupied at the time of the assessment • No smoke odor was detected in the building

FINDINGS

Based on the real time measurements the following findings are presented

1 Concentrations of CO and TVOCs were below applicable standards and guidelines 2 Seventeen (17) indoor measurement for temperature were withm and one hundred eleven (111) measurements were above the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55 1992 dunng the heating season (wintertime conditions) 3 All of the indoor measurements for relative humidity were within the ASHRAE recommended range of 30 to 60 percent for occupant comfort 4 All but one of the indoor measurements for CO2 were below the ASHRAE Standard 62 1999 recommended maximum concentration of <700 ppm above the background level The highest reading (1289 ppm) was measured in room 1005 at 10 59 AM with 31 occupants Levels above the recommended maximum do not indicate a health risk Carbon dioxide measurements are used as an indicator of available outdoor air The primary source of CO2 indoors is occupant respiration 5 All of the indoor measurements were below the NPAAQS of 65 pg/m^ 24 hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter One (1) of the one hundred twenty eight (128) instantaneous indoor readings was above the USEPA recommended concentration for sensitive individuals such as asthmatic people and children of 40 pg/m^ Three (3) outdoor measurements were above the NPAAQS of 65 pg/m^ 24 hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter Eleven (11) of the outdoor instantaneous measurements were above and one (1) was below the USEPA recommended concentration for sensitive individuals such as asthmatic people and children of 40 pg/m^

CITY_21MC100_003085433

NYC-WTC_000295849

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000295849Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →