Memo/letter: Indoor air quality, school IAQ

Machine-extracted title · confidence 50%

ATC report detailing IAQ measurements at NYC school; March 7, 2002.

NYC-WTC_000295787–000295791
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr Bernard P Orlan March 8 2002 Indoor Air Quality Assessment Page 4 H S for Leadership & Public Service (M894) ATCProiectNo 15 19125 0290 were above the USEPA recommended concentration for sensitive individuals such as asthmatic people and children of 40 pg/m^

* The measurements made during this assessment were instantaneous readings the NPAAQS is a 24 hour average

TVOC Concentration

The TVOCs concentrations were 0 ppm inside the building These concentrations were below the AIHA guideline for odor control of 1 ppm The outdoor TVOC concentration was also 0 ppm

OBSERVATIONS

During this assessment ATC noted the following • The interior of the building appeared clean and free of dust and debns • The building was occupied at the time of the assessment • No smoke odor was detected in the building

FINDINGS

Based on the real time measurements the following findings are presented

1 Concentrations of CO CO2 and TVOCs were below applicable standards and guidelmes 2 One (1) indoor temperature measurement was below and four (4) measurements were above the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55 1992 during the heating season (wintertime conditions) 3 One hundred and fifteen (115) relative humidity measurements were below the ASHRAE recommended range of 30 to 60 percent for occupant comfort Thirteen (13) indoor measurements were within the ASHRAE recommended range 4 None of the indoor respirable particle measurements were above the NPAAQS of 65 pg/m^ 24 hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter Two (2) of the one hundred twenty eight (128) indoor instantaneous measurements were above the USEPA recommended concentration for sensitive individuals such as asthmatic people and children of 40 pg/m^ Eleven (11) of the outdoor measurements were above the NPAAQS of 65 pg/m^ 24 hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter All of the outdoor instantaneous measurements were above the USEPA recommended concentration for sensitive individuals such as asthmatic people and children of 40 pg/m^

CITY_21MC100_003085355

NYC-WTC_000295790

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000295790Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →