Mr. Bernard 1’. Ori an February 6. 2002 Indoor Air (,.)Liality Assessment Page 3 I’. S. 15()M ATC Proiect No. 15-191 2.^-0289

R E A L,-T1 M r: 1a VI RON M ENT A I- MEASUREMENTS

A f C collected forty (40) sets of real-time environmental measurements consisting ot’twenty- nine (29) from inside the school building and eleven (11) from the outdoois. All three floors of the school building were surveyed. These result.s are described below .

field data sheets are found in Attachment 1. Readings began at 1 !:()() A.M. and concluded at approxiniateh 3:.3O P.M.

Indoor dry bulb temperature measurements ranged from VO.O^F to 76.3°F. Two (2) ineasLirement.s were above the range of 68 to 75°F (at 50 percent relative humidity) as lecommended by the ASFIRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature measurements ranged from 32.1 to 37.1 ^fh

/{ekitive Hiimidilv

fne relative humidity indoors ranged from 11.4 to 16.4 percent. /Ml of the measurements were below the ASHKAE-recommended range of 30 to 60 percent for occupant comfort. 'The outdoor relative humidity measurements ranged from 7.5 to 13.9 percent.

Ciirhnu Dioxide Conccnlrution

l.'arbon dioxide concentrations indoors ranged from 614 ppm to 1180 ppm. All of the (JOo measurements wa.s below the ASFIRAE Standard 62’.-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO? concentration was 519 ppm. Therefore, the maximum acceptable level of CO? at this k cat 1.011 was 1219 ppm (background level + 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as aii indicator o-'available outside makeup air. d'he primary source of CO? indoors is occupant respiration. The school building was occupied during ATC’s assessment.

Carhon Mtmoxide Concentration

Carbon monoxide concentrations indoors were 0 ppms for the interior readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 pprn. The outdoor CO concentration w'as 0 ppm for all collected readings.

Rcsjiirdhle Peirticulates (PM2.5J

Respirable particulate concentrations* indoors ranged between 6 ug/m^ to 22 pg/m^. None of the measurements were above the NPAAQS of 65 pg/m- 24-hoiir average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PM2.5 concentration for the ertire school building was approximately 15 pg/m^, The PM2.5 average concentration was below the I'SLI’A recommended concentration of 40 p.g/m4 for sensitive individuals / children. The outdoor respirable particulate concentration measurements ranged from 7 to 19 pg/m^ with an averageofl2pg/m3.

CITY_21MC100_0 02954083

NYC-WTC_000289344

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289344Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

IAQ assessment letter, PS150M, Mar 2002

NYC-WTC_000187665

Cover letter from ATC Associates submitting an indoor air quality assessment report for PS150M collected on March 25, 2002.

Similar indexed content

NYC-WTC_000375465

Indoor air quality measurements for P.S. 150M requested by BOE.

Similar indexed content

Compare copies and versions →