’ The measurements made during this assessment were instantaneous readings, the NPAAQS is
a 24-hour average.
Tl^OC Concentrations
'fVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC
concentration was also 0.0 ppm.
OBSEKVL4TIONS
During this assessment, ATC noted the following:
• There was no ccnstruction work going on in the plaza:
• The school building was occupied at the time of the assessment;
• No smoke odor was detected in the building
FINDINGS
Based on die real-time measurements, the following findings are presented:
1. Concentrations of CO2, CO and TVOCs were within applicable standards and guidelines;
2. None of the PM2,5 measurements were above the NPAAQS of 65 pg/m^ or above the
HSEP.A recommended PM2,5 concentration of 40 pg/m-’ for sensitive individuals and
childrcri.
3. Two (2) temperature measurements were above the range of 68 to 75® F (at 50 percent
relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season
(wintertime conditions).
4. All indoor measurements of relative humidity were below the ASHRAE recommended range
of 30 to 60 percent tor occupant comfort.
It is our pleasure to provide these indoor air quality services to the New 'I’ork City Board of
Education. If you have any questions about this report, please call (2l2| 353-8280, extension
261 01-212.
Sincerely, Reviewed by:
A TC ASSOCJA TES INC.
Andreas C. Andreou James R. Cohn, CIH, CSP
Senior Project Manager Regional Manager
Industrial Hygiene Division
Attachment
CITY_21MC100_002954084
NYC-WTC_000289345
OCR can misread numbers and units. Confirm readings against the page image before using them.