NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

IAQ report, 104 East 25th St, PS 89M

Machine-extracted title · confidence 25%

ATC report of IAQ measurements for PS 89M, March 12, 2002 referenced.

NYC-WTC_000360209–000360212
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

03/13/2002 12:29 FAX 212 353 8306 ATC iaoo4

Mr. Bernard P, Orlan March 13,2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATCProiectNo. 15-19125-0297

real-Time Environmental Measurements

ATC collected eighty (80) sets of real-time environmental measurenients consisting of seventy (70) from inside the school building and ten (10) from outdoors. All five floors of the school building were surveyed. Tltese results are described below.

Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded at approximately 11:30 A.M.

Temoeratyre

Indoor dry bulb temperature measmements ranged from 65.3°? to 74.2°F. Three (3) of the measurements were below the range of 68 to 75°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during tlie heating season (wintertime conditions). The outdoor temperature measurements ranged from 43.6 to 47,0°F.

Relative Humjdiiv

The relative humidity indoors ranged from 20.7 to 27,7 percent. All of the measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 43.0 to 47-3 percent-

Carban Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 468 ppm to 1135 ppm. All of the CO?, measurements were within the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO? concentration was 436 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1136 ppm (background level + 700 ppm). The highest CO2 measurement was collected from room 408. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of CO2 indoors is occupant respiration. The school building was occupied during ATC’s assessment.

CarbonMonoxidoCoticentration

Carbon monoxide concentrations indoors were 0 to 1 ppm. These concentrations were below the NPAAQS/ASIIRAE guideline of 9 ppm. The outdoor CO concentration was 0 ppm for all collected readings.

Respirable Particulates (PM2,5)

Respirable particulate concentrations* indoors ranged between 15 pg/m^ to 36 pg/m3. None of the measurements were above the NPAAQS of 65 ug/m^ 24-liour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PM?.5 concentration for the entire school building was approximately 25 pg/m3. The PM2,5 average concentration was below die USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged

CITY_21MC100_009253507

NYC-WTC_000360211

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000360211Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →