operational for the first two months of the project. Eventual repair of the elevator by others allowed access to the inner compartment. The elevator cab and the exterior top of the cab were vacuumed.

2.G.4. Basement (Study) The basement of the building is comprised of separate rooms: a trash compactor room, a motor room associated with the elevator shaft, a common access area from the street, and a fire protection equipment room. The brick walls of the basement were crusted with mud, indicating a high water level at some time in the building's history. These rooms were cleaned using the commercial HEPA equipment. Loose debris related to stone and mortar deterioration was vacuumed from the walls and ledges of the base of the elevator shaft. Small rocks, paper, debris, and rodent carcasses were removed.

2.H. Cleaning of Non-Study Commercial Units Commercial Units Lemongrass Grill, Food Exchange and Barber Shop; below-grade common areas; and two condensers on the roof were also cleaned. These areas were cleaned using cleaning methods as presented in Attachment 12, Synopsis of Cleaning Methods by Building Area. The condensers on the atrium roof were cleaned with a HEPA-filtered vacuum.

The sequence of procedures for vacuuming, wet wiping, waste management, and pre-cleaning and post-cleaning sampling mirrored the procedures used in the residential units. Management of waste was accomplished as the cleaning activities occurred. Disposal of debris was handled in the same manner as in the residential units. Cleaning of the HVAC systems presented the only significant difference from the cleaning procedures used in the residential units. A discussion of the types of HVAC systems contained in these commercial units and the procedures used to clean these HVAC systems follows.

Commercial Lemongrass Grill, occupies 2,351 square feet of space. A self-contained re-circulating HVAC system with no outdoor supply air is suspended above the floor in the South end of the restaurant. Return air enters the unit through a grill located in the front side of the unit. The air-handling unit is accessible through access doors on either side of the unit. The unit is enclosed in one-half inch of sheet rock. A supply trunk runs northward through the restaurant with three supply branches. A second source of duct is located adjacent to an exhaust hood for the cooking equipment. This system is separate from the HVAC and supplies makeup air to the hood area. Ambient air is drawn in from a grill above street level to a blower inside the building that leads to a supply trunk. Four supply grills are adjacent to the food exhaust hood.

Commercial Unit Food Exchange is a restaurant that occupies 2,324 square feet of space, running from Cedar Street at the South end through to Liberty Street on the North end. Two side-by-side air handlers that share the supply air duct system are supported above a decorative tinned acoustical ceiling. The supply duct system splits mid building and runs approximately fifty feet in two opposite directions. A water cooling tower is located outside the building on the building

21

CITY_21MC100_004204978

NYC-WTC_000276674

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276674Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →