NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
lines for dust.
2.G.2. Carpet Cleaning (Study)
Two methods were utilized to clean the carpets in the Chiropractor's Office and the Retail
Mattress Showroom; 1) Nilfisk vacuum with HEPA filtration, and 2) wet vacuuming. Carpets
were wet-vacuumed in the Chiropractor's Office and in the Retail Mattress Showroom, using
standard carpet shampooing equipment available to the public at rental stores. The carpets were
cleaned twice, sampled, and disposed as porous material. Initially, the carpets were cleaned
running in the direction of the room fi-om front to back (Liberty Street to Cedar Street). The
carpets were then cleaned again, in a direction crossing the room from side to side.
Warm water only was used in the Chiropractor's Office. Soap (carpet shampoo) and warm water
were used in the Retail Mattress Showroom. "Seven-in-One" brand professional carpet
shampoo, manufactured by Kent Investment Corporation, was diluted at two ounces per gallon of
water. This dilution achieved 1400-2000 square feet of cleaning coverage.
2.G.3. Common Areas (Study)
The common areas were the first areas of the building cleaned, in order to provide a dust free
area for Level D entry through the common spaces, and to provide a safe location for equipment
storage. All foyers, stairways, and halls were vacuumed using commercial quality HEPA
vacuums. All horizontal and vertical surfaces in the common areas were wet wiped where
possible. The common areas were re-cleaned as necessary due to traffic.
Stairwells were cleaned commencing at the Cedar Street doorway vestibule starting in the
stairwell at the ground entrance and proceeding to the rooftop access door. The stairwells were
then re-cleaned, following the same route back. The ceilings, walls, handrails, balusters, treads,
risers, fire protection equipment, lighting, and trim were included in the cleaning
The hallways of each floor were accessed through fire doors at the stairwell platform for each
floor. Access to each floor remained closed until each stair well had been cleaned from bottom
to top, and top to bottom. The hallways were cleaned in the same manner as the stairwells,
except that not all of the hallway walls were wet wiped. The second floor hallway floor was
covered with vinyl tile. It was wet wiped. However, the third and fourth floor walls were made
of plywood. Wallpaper originally applied to the wall surfaces had been removed, leaving a
rough paste finish that was not conducive to wet wiping.
Each hallway contained a utility room with a wall-enclosed trash chute to the basement of the
building. Some items were discovered in the utility closets. Boxes that were unopened were
vacuumed and left in place. Other items were packaged for disposal. The utility areas did not
seem to be affected by the WTC dust condition.
An elevator accessing each floor was located on the Cedar Street side of the building. It was not
20
CITY_21MC100_004204977
NYC-WTC_000276673
OCR can misread numbers and units. Confirm readings against the page image before using them.