NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
The assessment of the indoor environment began with a review of historical information on
hazardous substances that have been associated with building fires and collapses. Many
compounds, including combustion by-products such as dioxins and polycyclic aromatic
hydrocarbons (PAHs) were identified for further investigation, along with building materials
such as asbestos and fibrous glass. In addition, ambient air, indoor air, and indoor/outdoor bulk
dust monitoring data were reviewed. Data sources included EPA's ambient air and bulk
dust/debris monitoring program (www.epa.gov/wtc), OSHA's air/dust monitoring data and the
NYCDOH/ATSDR indoor air pilot program [NYCDOH, 2002]. A concerted effort also was
made to identify and review additional sources of WTC-related data from other governmental
agencies (e.g., U.S. Geological Survey, NYC Board of Education), academic institutions,
environmental organizations, and the private sector.
A semi-quantitative screening process was performed on the collected sampling data. Based on
fiequency-of-detection, concentration and inherent toxicity, contaminants that exceeded
health-based screening levels for the ambient air were identified. Dioxin and PAHs were added
to the COPC list by this process. In addition, building constituents with carcinogenic (asbestos)
or irritant effects (fibrous glass, silica) that were consistently and significantly found in bulk
debris and indoor dust samples were identified as COPCs [NYCDOH, 2002] . Finally, lead was
included based on a comparison of sampling data with existing regulatory standards.
Collectively, the resulting group of contaminants (asbestos, lead, dioxin, PAHs, fibrous glass and
silica) are called "contaminants of potential concern" or COPCs in this report.
Recommendations for action are based upon health-based benchmarks.
Table 1. Numeric criteria used for determining reoccupancy at 110-113 Liberty Street.
Values are from the draft document entitled “World Trade Center Indoor Air Assessment;
Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks".
Compound Air Settled Dust
Asbestos 0.0009 f/cc n/a
Polycyclic Aromatic Hydrocarbons (PAHs) 0.2 pg/m^ 300 pg/m^
Dioxin/Furan 0.001 ng/m^ 4 ng/m^
Lead 1 Pg/m^ 25 pg/tf (micro
vacuum
comparison
value 25 pg/ft’)
Fibrous Glass (Man-made Vitreous Fibers) lOS/L n/a
Silica (1 pg/m^ - 4 pg/m' based on analytical methods) 4 pg/m’ n/a
5
CITY_21MC100_004204962
NYC-WTC_000276658