NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
SECTION 1 - INTRODUCTION
1. A. Overview
As a result of continuing concerns expressed by residents regarding appropriate approaches to
cleaning their living spaces and potential health risks, EPA, in concert with FEMA and NYC,
began a study of a building that has been impacted by the collapse of the WTC. The building
was located on Liberty Street, just south of the WTC site. On June 14, 2002 EPA and its
contractors implemented a WTC Residential Confirmation Cleaning Study (the Study)
confirming the adequacy of various cleaning and vacuuming methods that may have been used
by residents and professional cleaning companies, in the aftermath of the attack to clean dust and
debris from residential living areas.
The effectiveness of the various Study cleaning methods were evaluated through the collection
and analysis of pre-cleanup and post-cleanup samples, and comparison of the resulting analytical
data to Contaminants of Potential Concern to determine if the cleaning method achieved health
based screening levels. The COPCs used in this study were: asbestos air by PCMe, lead air and
settled dust, dioxin air and settled dust, PAHs air and settled dust, fibrous glass (MMVF) air, and
crystalline silica (alpha quartz) air.. More detail on the selection of these compounds is in the
following section.
Data was also evaluated from other compounds that do not have health-based benchmarks, that
are not consider COPCs. These included asbestos air by PCM and TEM AHERA, asbestos
settled dust, calcite air and settled dust, gypsum air and settled dust, cristobolite air and settled
dust, tridymite air and settled dust, fibrous glass (MMVF) settled dust by wipe sampling, silca
settled dust by wipe sampling and total settled dust.
For the most part, cleaning continued in the residential units and commercial spaces until health
based benchmarks were achieved. Some areas required three cleanings.
The Cleaning and Sampling Sections of this report provide details on the cleaning and sampling
activities.
1. B. Development of Contaminants of Potential Concern (COPCs)
Under the auspices of the Indoor Air Task Force Working Group a committee was formed to
identify contaminants of potential concern (COPCs) and associated health based clearance
criteria for the lower Manhattan Clean-up Program. Among other purposes, this initiative was
intended to inform the selection of contaminants to monitor in the WTC Pilot Clean-up Study
and provide a measure of cleaning effectiveness by establishing health-based clean-up goals for
indoor air and settled dust. A draft of the COPC/Benchmarks report was peer reviewed on
October 21-22, 2002. The final report is still a work in progress. As such, the COPCs identified
for inclusion in the Study reflect those contaminants cited in the peer review draft of the
COPC/Benchmarks report.
4
CITY_21MC100_004204961
NYC-WTC_000276657
OCR can misread numbers and units. Confirm readings against the page image before using them.