asbestos, lead, dioxin, PAHs, fibrous glass and crystalline silica.
A summary of the significant conclusions of the Study are provided below. These include
observations about the building, cleaning techniques, and data collection techniques.
Conclusions Regarding Contamination of Building
• Established that the building had levels of WTC contamination prior to cleaning by EPA.
Nineteen of the twenty-five sites in the building exceeded health-based benchmarks.
Generally units facing ground zero had higher than average levels of contamination
within the unit for lead, asbestos, fibrous glass pre- and post-cleaning.
• Confirmed that visual observations of dust generally corresponded with levels of
contamination found in dust.
• Confirmed that mercury levels were below EPA’s health based benchmark.
Conclusions Regarding Cleaning Methods
• Observed that one cleaning method was not clearly superior to the others. However,
there was generally a reduction in the level of contamination from one cleaning to the
next regardless of the equipment used.
• Determined that all methods were able to clean to levels that met clearance criteria,
although some required multiple cleanings. The data suggests that more heavily
contaminated units required more cleaning events to meet the clearance criteria.
• Determined that all methods were extremely effective in reducing lead and fibrous glass
dust concentrations after one cleaning regardless of the level of contamination at the start
of the cleaning.
• Observed that the use of an Air Filtration Device (AFD) reduced the occurrence of
overloaded air sample filters and decreases the number of cleanings required to meet the
clearance criteria.
• Found that HVAC cleanings were effective in removing significant quantities of
contaminated dust.
Conclusions Regarding Data Collection Techniques
• Obtained inconclusive results on experiments conducted regarding comparisons of
modified-aggressive and aggressive air disturbance techniques.
• Obtained inconclusive results on experiments comparing different filter pore sizes and
comparing different sample pump flow rates.
• Determined that overall, clearance based on PCMe results was conservative to determine
if further cleaning is warranted. PCMe results also provide a good indication of reduction
of other compounds.