asbestos, lead, dioxin, PAHs, fibrous glass and crystalline silica.

A summary of the significant conclusions of the Study are provided below. These include observations about the building, cleaning techniques, and data collection techniques.

Conclusions Regarding Contamination of Building • Established that the building had levels of WTC contamination prior to cleaning by EPA. Nineteen of the twenty-five sites in the building exceeded health-based benchmarks. Generally units facing ground zero had higher than average levels of contamination within the unit for lead, asbestos, fibrous glass pre- and post-cleaning. • Confirmed that visual observations of dust generally corresponded with levels of contamination found in dust. • Confirmed that mercury levels were below EPA’s health based benchmark.

Conclusions Regarding Cleaning Methods • Observed that one cleaning method was not clearly superior to the others. However, there was generally a reduction in the level of contamination from one cleaning to the next regardless of the equipment used. • Determined that all methods were able to clean to levels that met clearance criteria, although some required multiple cleanings. The data suggests that more heavily contaminated units required more cleaning events to meet the clearance criteria. • Determined that all methods were extremely effective in reducing lead and fibrous glass dust concentrations after one cleaning regardless of the level of contamination at the start of the cleaning. • Observed that the use of an Air Filtration Device (AFD) reduced the occurrence of overloaded air sample filters and decreases the number of cleanings required to meet the clearance criteria. • Found that HVAC cleanings were effective in removing significant quantities of contaminated dust.

Conclusions Regarding Data Collection Techniques • Obtained inconclusive results on experiments conducted regarding comparisons of modified-aggressive and aggressive air disturbance techniques. • Obtained inconclusive results on experiments comparing different filter pore sizes and comparing different sample pump flow rates. • Determined that overall, clearance based on PCMe results was conservative to determine if further cleaning is warranted. PCMe results also provide a good indication of reduction of other compounds.

3

CITY_21MC100_004204960

NYC-WTC_000276656

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276656Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →