Lemongrass Grill occupies 2,351 square feet of space. It utilizes a self-contained re-circulating
HVAC system, with no outdoor supply air, that is suspended above the floor in the south end of
the restaurant. Return air enters the unit through a grill located in the front side of the unit. The
air-handling unit is accessible through access doors on either side of the unit. The unit is enclosed
with one-half-inch sheet rock. A supply trunk runs northward through the restaurant with three
supply branches. A second source of duct is located adjacent to an exhaust hood for the cooking
equipment. This system is separate from the HVAC and supplies makeup air to the hood area.
Ambient air is drawn in from a grill above street level to a blower inside the building that leads to
a supply trunk. Four supply grills are adjacent to the food exhaust hood.
The Food Exchange is a restaurant that occupies 2,324 square feet of space, running from Cedar
Street at the South end through to Liberty Street on the north end. Two side-by-side air handlers
that share the supply air duct system are supported above a decorative tinned acoustical ceiling.
The supply duct system splits mid-building and runs approximately fifty feet in two opposite
directions. A water cooling tower is located outside the building on the building atrium. The air
handlers use a common air return with no makeup air being drawn from outside the building.
Access to the duct work on the north side of the building must be through the access grill
openings, because the ceiling is enclosed in sheet rock. Access to the duct work on the south side
is through a suspended ceiling. The ceiling tiles in the area of the duct work and the insulation
wrapping the duct work were removed prior to cleaning the ducts. The space from the suspended
ceiling to the upper deck, including the grid work, was vacuumed. An isolation wall was
fabricated to bar the north side from the south side.
The services of an HVAC consultant were secured to develop site-specific cleaning procedures
for the Lemongrass Grill and the Food Exchange, and to stipulate necessary controls, protective
measures, and standards for the cleaning and sampling confirmation process. These procedures
are provided in Attachment I, HVAC Cleaning Procedures.
The Barber Shop is situated below grade. The unit contains a ductless A/C system with a remote
condenser/compressor unit. The condenser/compressor unit is located above the entrance door
that accesses Liberty Street. The air handling system and the condenser/compressor unit was
cleaned in an effort to remove accumulated residual dust and debris so that the units could be
handled for disposal by the building owner.
2.9 Cleaning of Building Exterior/Roof
Cleaning of the building exterior and the rooftop was accomplished and monitored by the
NYCDEP. NYCDEP hired an asbestos abatement contractor to accomplish this task. Cleaning
of the building exterior was initiated at approximately the same time that cleaning of the interior
of the building began. NYCDEP subcontractors were required to vacuum and wash the building
exterior twice over a two-day period before acceptable results were achieved.
The building has two roof elevations: An atrium roof at the second floor level, and a roof at the
fifth floor level. Four residential compressor/condenser units are situated on the fifth floor roof.
These service ductless air conditioning units in the residential apartments. Prior to the study,
these units were cleaned by outside contractors. Three commercial compressor/condenser units
are situated on the atrium roof of the building. These units service the Chiropractor's Office, the