NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
NYC-WTC_000145027–000145344Folder label: “NO INFO”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Maintain the cleaning zone under negative pressure using a HEPA filtered air filtration device whenever possible.
11.3 Site-specific Cleaning Procedures
11.3.1 Lemon Grass Restaurant
This is a 2,351 sq ft space with variable ceiling height. One air handling unit is located above the ceiling toward the south end of the floor. This is a recirculating air unit with no outdoor air supply. Return air enters the unit through a grille located in the side of the unit. The air handling unit is accessible and is provided with access doors. The air handling unit distributes supply air through a main supply air duct and several branch ducts. Supply air diffuser openings are located on the underside of the supply duct (most of the diffusers have been removed). The supply diffuser openings extend in a line to the north of the air handling units and are spaced approximately 15’ apart. There are approximately four 18” supply diffuser openings located to the north of the air handling unit. There is a separate ducted make-up air system that delivers outdoor air to the cooking stations. The make-up air system consists of a single duct with diffuser openings on the underside of the duct, and a blower assembly that is located in-line with the duct. Outdoor air is provided to the make-up air system through a ducted outdoor air intake located in an exterior wall of the building approximately 10’ above ground level.
VENTILATION SYSTEM COMPONENTS TO BE CLEANED
The following system components will be cleaned in the Lemon Grass Restaurant:
a. Air handling unit and components b. Reheat Coil c. Supply air ducts and terminal difiusers d. Makeup Air System e. Dissembled Duct Sections on Floor
CLEANING PROCEDURES
General: Any interior surfaces of the air handling unit or ventilation system that are porous shall be cleaned using manual HEPA vacuuming methods. After successful completion of visual inspection and verification sampling, a lockdown encapsulant shall be applied to the porous surfaces using a hand-operated sprayer or brush, using care not to coat electrical or mechanical components.
Note that if any dissembly of the air handling units is required to complete the work, the air handling unit shall be reassembled by a qualified HVAC professional after all parts are dry and are verified clean.
Note that all HEPA air filtration devices and HEPA-filtered vacuum collection devices shall be exhausted to the outdoors.
12
NYC-WTC_000145216
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
20 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
13 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
11 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
20 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
12 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
15 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
25 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000150209
Laboratory report listing PCM and TEM asbestos air sampling results collected on September 26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.
Cited alongside this record in an Ask answer