NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
NYC-WTC_000145027–000145344Folder label: “NO INFO”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Non-Study
The Food Exchange 1^ floor, basement and sub-basement Cedar & Liberty Street
Cleaning Method: Test 4A - Surface cleaning using industrial HEP A filtered vacuums. Area air filtration utilizing an air filtration device (AFD). Soap and water wet wipe of all horizontal surfaces. Equipment Used: Nilfisk™ Vacuum (CFM 127), AFD Filtration Status: HEPA Unit Size: 1®* floor- 2,324 sq. ft.; 31,606 cu. ft.; basement- 2,596 sq. ft.; 36,344 cu. ft. AFD Status: Required AFD Specification: 400/600 cfm Unit air exchange rate: 1^ floor 15.80 min @ 2000 cfm, basement 18.17 min @ 2000 cfin. Minimum Air Exchange Required: Every 30 minutes
Unit Description; The restaurant encompasses approximately 5,000 square feet. It may be entered from either a Cedar Street or a Liberty Street entrance. The establishment is comprised of three floors. The first floor is at street level. This floor was used for food service and customer dining. The lower level (basement) was used for food preparation and storage. The third level (sub-basement) was used for storage of restaurant equipment. Ceramic tile covers the floor area in both the dining room and the basement. The floor of the sub-basement is packed soil. All exterior windows had been blown inward depositing significant amounts of dust on all surface areas of the first floor. Minimal dust was present in the basement. The first floor ceiling by the Liberty Street entrance is made of gypsum board. The ceiling on the Cedar Street entrance consists of suspended acoustical tile covered with a decorative tin facing. Above the suspended ceiling is a two-foot void space that houses the HVAC system for the establishment. The basement ceiling is a suspended fibrous tile ceiling. The void space above both suspended ceilings and the gypsum ceiling, contained both WTC related and non-WTC related dust. Asbestos pipe insulation was present in the void space of the basement. Grills, refrigerators, tables and chairs are present on the first floor. The basement contains walk-in refrigerators, preparation tables, stoves, dishwashing areas, and dry good storage. Prior to cleaning, all open and bulk stored food, fibrous ceiling tiles in the basement, and wrap insulation that had surrounded the HVAC systems, were disposed of. The HVAC system located in the void space above the dining room ceiling consists of two air handlers that provide heat or cooling to the first floor via separate solid metal supply ducts. The system return is from the dining area and void space located above the first floor. Cleaning of this system was performed by a subcontractor in accordance with a site-specific scope of work prepared by Covino Environmental Associates Inc.
22
NYC-WTC_000145198
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
20 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
13 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
11 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
20 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
12 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
15 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
25 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000150209
Laboratory report listing PCM and TEM asbestos air sampling results collected on September 26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.
Cited alongside this record in an Ask answer