NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 06/10/09
Floor Zip Borough Block Lot Squad # Badge #
Various_________ 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze_____ F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
462 Getty Avenue Clifton______
State Zip Phone Sample Number
NJ 07011 973-772-3660
Third Party Air Monitor Owner’s Name
TRO Fnvirnnmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 212-221-7822 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 10:45 pm to 11:45 pm
I arrived at the premise at 10:45 pm and met with Rocco - LVI Supervisor, who informed me that
that electrical panel was repaired and power was back to normal.
LVI schedule informed that activities include: clear floor, scrape fireproofing, demo, load out
on V'floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective
equipment to enter the regulated area on r'floor.
Three workers were present for the decon maintenance, cleaning shower chambers and organizing
the clean room. Negative air pressure on the floor was -0.042.
V' Floor - 53 Asbestos Handlers were present inside the work area. Workers were found on
scaffolds at the north side of the area #5 cutting air ducts from the ceiling, metal panels from the
column, spraying debris and placing into the boxes. At the north and south/east sides of the area #5
workers were on scaffolds and scissor lifts scraping fireproofing, spraying with amended water,
cleaning the floor, picking up debris, placing into the boxes.
At the north/west side vestibule workers were on scaffolds scraping horizontal and vertical beams,
spraying the area with amended water. Others were cleaning the floor from debris, preparing
and loading out boxes through the waste decon. 20 Gaylord boxes were on the floor ready
for load out.
Inspection was done on micro trap machines and tents. Electrical panel was repaired, all 40 micro
trap machines were powered on and 5 stand by.
At the east side of the work area I observed: 1. Two spots of excess water on the floor;
2. Air monitoring pump inside the Tent #1 was not powered on.
I took photos, then Handler Supervisor Victor was advised to pick up excess water, and
conduct emergency repair of pump. He directed workers, and defects were repaired immediately.
After following the decontamination procedure I exited the work area.
I met with Rocco - LVI Supervisor at the LVI office to discuss the findings of the inspection.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000131048