NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 03/12/09
Floor Zip Borough Block Lot Squad # Badge #
Various 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 6:20 pm to 7:15 pm
I arrived at the premise at 6:20 pm. LVI schedule informed that activities include:
clear floor, cut ducts, demo walls, ceilings on V* floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal
protective equipment to enter the regulated area on Vfloor Three workers were present
for the decon maintenance, cleaning the shower chambers and organizing the clean room.
Manometer reading of the negative air pressure was -0.045.
V’ Floor - 58 workers were present inside the work area. Workers were clearing the
shafts from debris, spraying with amended water, placing debris into the boxes.
Two workers on mezzanine inside the engine room were cutting and removing conduit.
At the east side hallway workers in two scissor lifts were breaking down the hard drop
ceiling, using hammer and electrical power tool, attached to the HEPA vacuum.
Four workers harnessed in two scissor lifts were breaking plaster ceiling into the
pieces on the west side hallway, bringing down pieces from ceiling to the floor; one worker was
spraying the area with amended water.
Other workers were: cutting metal into small pieces at the various locations,
placing into the boxes and spraying with amended water; preparing boxes, wrapping beams
with poly, loading out sealed and sprayed boxes through the north side waste decon.
A large amount of debris and poly wrapped beams still exists on the floor.
I observed one light bulb without protection on it. Foreman was advised, and he contacted
electricians to inform them that light bulb needed to be covered with cage.
56 Gaylord boxes were on the floor ready to be taken out. 35 micro trap machines were
powered on and 5 on stand by. Inspection was done on micro trap tents.
After following the decontamination procedure I signed the log book and left the decon.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor's Initia'
J
Borough l=Mantiattan 2=Bronx 3=Brooklyn 4=Queens 5=Richniond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code I = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000130791
NYC-WTC_000181933
OCR can misread numbers and units. Confirm readings against the page image before using them.