‘IS* 4 REar’ t J NOV 25 WHIER POLLUTION ^uNTROt mailroom
November 23, 1983
Seelye Stevenson Value & Knecht, Inc. Engineers & Planners 99 Park Avenue New York, NY 10016
RE: North Access Connection, 10th Avenue Tunnel Amtrak, Borough of Manhattan
Dear Sir:
In reply to, your submittal of 95Z plans with a letter dated November 10, 1983 on the above referenced project, please be advised of the following specific commetns of this department:
A) Drawing No. C-Ul;
1. Show stationing and invert elevations at all existing manholes.
2. Show the existing sewer exactly as per MTA Contract No. 1-02-21064-0-0 ie, locations where it is plugged, abandoned etc.
3. Label the drain and expansion joint manhole.
B) Drawing No. C-D2:
1. Manhole No. 2 should be pressure relief manhole and not type A-1 manhole. Submit details.
2. Manhole No. 1 should be a chamber and not type A-2 manhole. Submit details and structural computations.
C) Drawing No. C-UTl:
1. Show stationing of manhole No. 1 and existing manhole.
-2. Manhole No. 1 will be a chamber and M.H. 2 will be a pressure relief manhole.
3. Show angle of deflection between the proposed 24" and 30" R.C.P. class III pipes at proposed manhole No. 1.
-cont-
NYC-WTC_000165831
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
1 shared topics · Same agency, volume and box · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗1 shared topics · Same agency, volume and box · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165377
Letter from DEP Bureau of Sewers regarding unreviseed drawings and as-built records for the tunnel project.
1 shared topics · Same agency, volume and box · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗1 shared topics · Same agency, volume and box · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165790
Letter provides specific design comments regarding roof slab thickness and removable slab configuration requirements.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165786
Department of Environmental Protection memo reviewing structural computations for a proposed sewer chamber, providing specifications for roof slab thickness and steel values.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗1 shared topics · Same agency, volume and box · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165322
Department of Environmental Protection letter providing design review comments on tunnel project contract drawings, requesting pressure relief manhole details, existing sewer…
1 shared topics · Same agency, volume and box · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗1 shared topics · Same agency, volume and box · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165536
March 15, 1982 DEP letter providing engineering requirements for a telephone manhole load above the proposed 13-inch sewer line.
1 shared topics · Same agency, volume and box · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗1 shared topics · Same agency, volume and box · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
No available related records indexed in this group.
More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 51 Chambers Street · 1 pages · confidence 0.00 · verify page 2
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Filed in the same folder
Filed in the same folder
Filed in the same folder
Filed in the same folder
Filed in the same folder