NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 44/P.A WTC C-81, DEY St. Replacement Sewer (WTC-DEY ST UNDERPASS)
Document / 2 pages

DEP Sewer Plan Comments, WTC-DEY St Underpass, Oct 1981

Machine-extracted title · confidence 95%

Letter from DEP to Port Authority regarding insufficient trench width and required pipe specifications for a rerouted sewer at the World Trade Center underpass.

NYC-WTC_000165589–000165590

Folder label: “P.A WTC C-81, DEY St. Replacement Sewer (WTC-DEY ST UNDERPASS)

Page image
Scanned page image, NYC-WTC_000165590
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

j -2-

,4) Complete structural details of manholes No. 1 & 2 should also be shown on submitted plans since they are non-standard. In this regard, there is an apparent interference condition shown at section F-F on drawing WTC-C4-81, between a 3” electrical duct, A 12-3" tel. duct bank, and the proposed manhole No. 1. No utilities shall be permitted to interfere with any sewer structure. 5) No existing sewer house connection shall be compromised as a result of any sewer abandonment in this project. Although no house connections are indicated on the plans, if any such connections are found in the course of construction, they must be continuously maintained and if disturbed, be re-connected before completion of the work. 6) The plans do not clearly differentiate, on every sheet, between existing structures to be maintained, abandoned, or rerouted. This should be corrected on revised plans. 7) There are two proposed steam drains shown to be connected to new manhole No. 3, one of which apparently does not pass through a cooling chamber. No steam may be permitted to enter a sewer without first being codied to a temperature not greater than 150 Deg. F. Please submit three (3) complete sets of plans revised in accordance with the comments stated aboved and marked in red on the enclosed plans, for further review.

Encl. cc; DiMartino Novotny Very truly yours. Pocci/Saia Farag/Yee Swedlow (3^^'^ Suspense MS: Ip FREDERICK NOVOTNY, P.E., CHIEF Div. of Sewer Regulation & Control

NYC-WTC_000165590

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165590Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP letter re WTC river intake plans, May 1982 · Box DEP Box 44

NYC-WTC_000165078

Department of Environmental Protection letter dated May 28, 1982, providing comments on submitted plans for relocating river water intake lines at the World Trade Center.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.934

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →