-2-
9. The existing and proposed structures will be shown on plans and profiles appearing in Drawing Nos. C-11 and S-28. 10. On Drawing Nos. C-12, C-13 and C-13A, the 12" storm sewers shown at track level were part of the original railroad drainage system installed at time of railroad construction. n. Structural computations signed and sealed by a N.Y.S.P.E. will be submitted for the flow distribution maintenance, flow adaptor and flow redirection chambers will be submitted. Hydraulic design of the connection piece between the flow adaptor chamber and manhole No. 2 is based on chamber design examples provided by the Bureau of Sewers (See Attachment). The "90° BEND" labeling shown on Drawing No. S-28 is incorrect and will be changed to read "FLOW REDIRECTION CHAMBER". Manholes Nos. 1, 2 and 3 are not standard manholes therefore their design details are shown on Drawing No. 30A. Information regarding type of catch basins and proposed 15 inch diameter sewer will be added to Drawing No. S-28. 12. Deflection angles and radii, where required, are shown on Drawings Nos. S-30 and S-30A. 13. A note will be added at the location of each abandoned sewer shown on Drawing No. S-28. This note will read: "NO HOUSE CONNECTIONS ARE LOCATED WITHIN THESE LIMITS" (of abandonment). 14. Drawing No. C-21 will be submitted as part of contract drawings. 15. Because of multi-disciplinary requirements of this project, the N.Y.C. standard details for catch basin type 3, etc. have been included for contractor's guidance, as shown on drawing Nos. C-19 and C-20.
4
/004
NYC-WTC_000165391
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165322
Department of Environmental Protection letter providing design review comments on tunnel project contract drawings, requesting pressure relief manhole details, existing sewer…
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165536
March 15, 1982 DEP letter providing engineering requirements for a telephone manhole load above the proposed 13-inch sewer line.
1 shared topics · Same agency, volume and box · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165522
Technical diagrams and tables showing proportions of value when flowing full for sewer design calculations related to the WTC project.
Same agency, volume and box · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165584
Department letter providing specific engineering requirements for a telephone manhole load and sewer centerline location.
1 shared topics · Same agency, volume and box · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗1 shared topics · Same agency, volume and box · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165377
Letter from DEP Bureau of Sewers regarding unreviseed drawings and as-built records for the tunnel project.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165506
June 5, 1984 internal DEP memorandum forwarding a sewer maintenance report by E.A. Britton regarding the WTC Dey Street project.
1 shared non-person entities · Same agency, volume and box · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
No available related records indexed in this group.
More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000165289
Environmental Protection Department record related to tunnel project between W. 33rd and W. 38th Street.
Filed in the same folder
NYC-WTC_000165290
Letter enclosing a signed agreement between DEP and a contractor regarding sewer work in the vicinity of 11th Avenue.
Filed in the same folder
NYC-WTC_000165299
DEP legal correspondence regarding tunnel construction and sewer work in vicinity of 11th Avenue and W. 33rd Street.
Filed in the same folder
NYC-WTC_000165301
DEP approval of final contract plans for tunnel project from W. 33rd to W. 38th Street with construction specifications.
Filed in the same folder
Filed in the same folder