NYC 9/11 Public Portal Document

Greenwich to Bdway between chambers and Murray

Cleanup work continues to be conducted in the area fi'om Greenwich to Broadway, between Chambers and Murray. Air monitoring was conducted in this area in an effort to move the site perimeter fi'om chambers to murray. Four air samples were taken in the proposed area each day. These results were as follows: 4>*-« 9/23/01 Park Place and church .01 fibers/cc Park Place and Greenwich .014 fibers/cc Murray and Church .007 fibers/cc wOOl Murray and Greenwich < .01 fibers/cc

9/24/01 Park Place and church .007 fibers/cc Park Place and Greenwich .012 fibers/cc Murray and Church .017 fibers/cc Murray and Greenwich .009 fibers/cc

9/25/01 Results expected at lOOOhours

101 Murray St

Indoor air monitoring indicates it is below clearance levels. Although, it remains inside the site perimeter and outside air has not been cleared, onsite emergency personnel should be able to use this facility.

Other agencies have used TEM Asbestos analysis rather than PCM which is what DEP is using. Because of tins they may feel it appropriate to open an area if TEM structures are below background. The problem with tWs approach is that this is a dynamic location effected by many factors. This approach would work better indoors in an enclosed static environment. 1116 PCM approach looks at the number of fibers in a specific size range rather than asbestos fibers. Therefore this approach errs on the conservative side. Therefore if we can insure that the fiber count remains below .01 fibers/cc we can be assured that there are no exposure and cleanup issues. Because this site is dynamic TEM results might give a false sense of safety since the number of asbestos fibers can change depending which construction vehicles travel through the site. In addition, increased winds which move debri fi-om ground zero onto site fi'om different locations can change asbestos count. Thore is also the consideration of contamination fi'om adjacent areas migrating with rain water. That’s why we believe the key is to sustain that the fiber count stay below the clearance level rather than worry about specific asbestos fiber counts. As

NYC-WTC_000148848

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148848Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP WTC General Correspondence Form · Box DEP Box 10

NYC-WTC_000149798

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

30 shared non-person entities · Same agency, volume and box · similarity 0.971

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →