NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
254 shared non-person entities · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
NYC-WTC_000146129–000146748Folder label: “EPA OIG LAW”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Final Technical Report of the Public Health Investigation Page28 of56 0.003 f/cc). Six of these air samples (from 3 common areas and 3 residences) had higher levels of fibers In air than the comparison areas above 59th Street (Table 8). Four of these areas had measurable levels of SVF In the settled surface dust. All six-air samples were re-analyzed by TEM to determine If the fibers present Included asbestos fibers. Asbestos fibers were not found In these six air samples (Table 8). A third analysis was done by SEM to determine If SVF fibers were present in those air samples from areas with SVF In the settled surface dust. SVF fibers were found In three of these air samples at concentrations from 0.000037 f/cc to 0.000255 f/cc. Although SEM Is a more sensitive method, detecting thinner fibers than PCM, reported SVF levels were well below the PCM method detection limit of O.OOlf/cc. SVF fiber concentrations In the comparison areas above 59th Street ranged from none detected to 0.000087 f/cc. Although air samples from comparison areas above 59th Street were not re- analyzed by TEM, no asbestos fibers were noted on the subsequent SEM analysis for SVF. Therefore the six air samples that had total fiber counts greater than comparison areas above 59th Street were not elevated due to either asbestos or SVF fibers.
There were 15 out of the 83 (18%) indoor areas in lower Manhattan with measurable asbestos In the settled surface dust, 10 residences and 5 common areas (Table 9). Nine of these residences were sampled aggressively (the air exhaust of the vacuum used for settled dust sampling was used to stir up all dust Into the air before an air sample was taken). Four of these aggressively sampled residences had measurable fiber levels In air ranging from 0.001 f/cc to 0.003 f/cc. One residence was occupied and could not be aggressively sampled. Air sampling at that location indicated <0.001 f/cc by PCM analysis. Because the levels found were within the range measured In the comparison areas above 59th Street, no TEM or SEM re-analysis was performed on these air samples. Therefore the composition of these fibers is unknown (i.e., asbestos, SVF, cellulose).
None of the common areas were aggressively sampled because all of these areas were open to the public. Of the five common areas with some asbestos In the dust, three had measurable levels of fiber In the air ranging from 0.001 f/cc to 0.002 f/cc. One area In building 5 where there was not enough settled surface dust to sample had an airborne fiber count of 0.002 f/cc. No TEM or SEM re-analysis was performed on these air samples, and the composition of these fibers is unknown (I.e., asbestos, SVF, cellulose).
b. Outdoor Air
Six of the 14 lower Manhattan outdoor locations sampled had detectable levels of asbestos in the settled surface dust, Indicating a potential in these locations for asbestos fibers to become airborne. Air sampling indicates three of the locations did not have detectable fibers in the air (Table 9). The air samples from buildings 1, 2, and 5 did have fibers detected at levels from 0.001 f/cc to 0.003 f/cc. Of the 15 locations where no settled surface dust samples were taken, the majority of the results showed <0.001 f/cc in the air, with only 4 samples reported at the
http://www.atsdr.cdc.gov/asbestos/lowermanhattan/ResSamp_ Sep2002_Text.html 07/18/2003 NYC-WTC_000146688
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
254 shared non-person entities · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
21 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093400
A license agreement document regarding exterior cleaning services for the property at 65 Liberty Street.
19 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132519
A DEP results table showing daily asbestos air monitoring data at 100 Trinity Place from October to November 2001.
29 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104846
Fax cover sheet transmitting permit application documents for work at 102 and 104 Greenwich Street to the NYC DEP on December 3, 2001.
12 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099112
Invoice from Fiber Control, Inc. dated November 27, 2002, for exterior cleanup services at multiple sites including 113 Nassau Street.
8 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000130799
Invoice from Benjamin Kurzban & Son Control, Inc. for roof work completed at 15 Dutch Street.
13 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113167
Invoice from Fiber Control Inc. for cleaning services on the facade of 54 Warren Street.
13 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099818
Billing record for asphalt and gravel roof cleanup services performed at 55 Nassau Street in November 2002.
8 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119790
Invoice from Fiber Control Inc. for DEP environmental protection services at 14 Barclay Street.
8 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000122774
An invoice from Fiber Control Inc. dated August 2002 for facade services performed at 179 Broadway.
11 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121922
Invoice dated October 2002 for environmental remediation services performed on the exterior of 118 Chambers Street.
9 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000178388
Comprehensive report on airborne and dust exposures in Lower Manhattan following the September 11 attacks, published by the Department of Health.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178388
Comprehensive report on airborne and dust exposures in Lower Manhattan following the September 11 attacks, published by the Department of Health.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Operational period plan from the FDNY detailing actions for December 21, 2001 at the World Trade Center site.
Cited alongside this record in an Ask answer
Operational period plan from the FDNY detailing actions for December 21, 2001 at the World Trade Center site.
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
NYC-WTC_000153382
Document arguing that respirator safety issues fall under OSHA jurisdiction and should be removed from the EPA review.
Cited alongside this record in an Ask answer
NYC-WTC_000138846
OSHA transmits NYS DOL data report containing sample summaries and worker information for WTC.
Cited alongside this record in an Ask answer