NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
NYC-WTC_000145027–000145344Folder label: “NO INFO”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
APPENDIX B INSTALLATION OF SERVICE OPENINGS IN AIR HANDLING SYSTEMS
[B. 1] Service openings in Sheet Metal Ventilation System Components: Any Service openings shall be made in such a way as to not significantly weaken the structural integrity of the metal ventilation system component and provide an air tight seal once secured. Ventilation system/duct cleaning firm must provide a finished surface deemed visually acceptable by the Client and in the opinion of the Client, not reduce the building's aesthetic qualities. Work cut and patched in an unsatisfactory manner shall be removed and replaced by the Ventilation system/duct cleaning firm at no additional cost to the Client. Upon completion of inspection and/or cleaning services, the Service openings shall be sealed in accordance with job specifications, with one of the following closure techniques:
(1) Install gasketed removable Access Doors.
(2) Install sheet metal panels fastened with sheet metal screws and sealed with silicone chalk, mastic or duct sealant.
[B.2] Service openings in Externally Insulated Sheet Metal Ventilation System Components; (See [C.l] Service openings in Sheet Metal Ventilation System Components) Upon closure of Access Hole, external insulation must be replaced as necessary and the edges secured with either an approved water-based bridging encapsulant for canvas-wrapped insulated duct exteriors or reinforced 4” wide foil tape on foil-faced insulated duct exteriors.
[B.3] Service openings in Fibrous Lined Sheet Metal Ventilation System Components: Any Service openings shall be made in such a way as to not significantly weaken the structural integrity of the metal ventilation system component or create fiber shed from the internal insulation at the cut area once the Access Hole is closed. Upon completion of inspection and/or cleaning services, the Service openings shall be sealed in accordance with the following closure techniques:
(1) Install gasketed, insulated Access Doors. The cut edge of the internal insulation lining at the Access Hole must be sealed with an approved Bridging Encapsulant to prevent fiber shed, and the insulation on the cover plate should fit securely in the cut-out area.
(2) Pressure fitting round hole plugs (for Service openings 3" diameter or smaller in low/medium positive air pressure applications) after an approved ventilation system Bridging Encapsulant has been applied to the cut edge of the internal insulation to prevent fibershed. (3) Install sheet metal panels affixed with similar insulation to match the removed portion of insulation from the service opening, fastened with sheet metal screws and sealed with silicone chalk, mastic or duct sealant. The cut edge of the internal insulation lining at the Access Hole must be sealed with an approved bridging encapsulant to prevent fiber shed, and the insulation on the cover plate should fit securely in the cut-out area.
1
NYC-WTC_000145225
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
20 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
13 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
11 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
20 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
12 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
15 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
25 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000150209
Laboratory report listing PCM and TEM asbestos air sampling results collected on September 26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.
Cited alongside this record in an Ask answer