samples, EPA Project Tracking Numbers, the laboratory address, date, and sample IDs in an
agreed upon electronic format or website approved by EPA within 24 hours of activity.
5. The Monitoring contractor shall evaluate all HVAC systems in all residential buildings where
‘-'Isviiiing will lake place to determine if these syslcins liax e been impacted by du.$t or debris
Trade Center and if these systems requife'glgWmgrTncases
■wESFclHnfiigTTrequestedToFZwEoIFBiulSngTthebinldingVHVAC system will be
evaluated as a whole. In cases where cleaning is requested for individual residential unit,
portions of the HVAC system dedicated to that unit vyill be evaluated. No residential or
common space shall be cleaned until the HVAC system has been e\ aluatpd and cleaned as
necessary.
If -Jif'
The Monitoring contractor shall inspect HVAC s^&ms or ppfcons thereof cleaned to verify
cleanlrness.
HVAC assessments, cleaning, and cleanliness inspections shall be conducted in accordance
with the National Air Duct Cleaners Association (NAI )C.\) Cienerul Specification for the
Cleaning of Commercial Heating, Ventilating and Air Condit inning Sj stems and theNADCA
Assessment, Cleaning and Restoration Standard (ACK 2002). Qualified personnel shall
perform the HVAC evaluation and cleanliness inspections. At a minimum such personnel
shall have an understanding of HVAC system design iuid experience in utilizing accepted
indoor environmental sampling practices, current industry HVAC cleaning procedures, and
applicable industry standards.
Ji’
Deliverables
.. iS"
A
'I'hc Project Mondor shall review all deliverables prior to submission to EPA. The review
shall assure that each deliverable is accurate and complete, technically sound, and free of
clerical error.,.
The Project Monitor shall record if the HVAC systems have been evaluated and cleaned
subsequent lo September 11, 2u01. If yes, when and by whom. This information shall be
PllVided via I-21. or an agreed upon alternative electronic format or website approved by
EPA within 24 hours of activity.
f). In the event that mold is observed in a residence during the pre-cleaning inspection, the
'^nitoring Contractor will contact the NYCDOH and EPA.
IMhcables
The Project Monitor shall record if mold is present and notify the NYCDOH and EPA. This
information shall be provided via EPA Indoor Air web database or an agreed upon alternative
electronic format or website approved by EPA within 24 hours of activity.