The Project Monitor shall complete chain-of-custody forms and record the number of wipe
samples, EPA Project Tracking Numbers, the laboratory address, date, and sample IDs in an
agreed upon electronic format or website approved by EPA within 24 hours of activity.
9. The Project Monitor shall schedule and oversee the cleaning operations of the Cleaning
Contractor. No residential, common space or HVAC system shall be cleaned until the exterior
of the building has been cleaned or has been inspected and found to be free of dust or debris
form the collapse of the WTC. No residential or common spaq^iall ^Beaned until the
HVAC system has been evaluated and cleaned as ni ;ssary. Ifasda ing problem arises
the Project Monitor should contact EPA. The Proje Monitor^ C iinate daily access
for cleaning and sampling with residents, owner^ ie Cleaning Coi a«r and sampli®
technicians.
■Ibi—rf*'
10. The Monitoring Contractor shall provide sufficient pc 'sonnel to provii ^dic (3-
4hours/unit) oversight of the Cleaning Contractor tO vedl work is being conducted in
accordance with the Cleaning Contact Scope of Work
11. The Project Monitor shall verify that the Cleaning Contrac |bg properly trained and
certified NYSDOL and NYCDEP
■Wb:
12. The Project Monitor shall conduct routine qt^.^_____ _:e inspections during the course of
cleaning and concur by initialing thB cieanir^^Checklist (to'^developed) for tasks completed
in compliance with the Cleaqj^^ontra^Bcope of Work
Deliverables
oject Monitor s (submit the completed Cleaning Checklist via F2L or an agreed
Idbiative electn Iformat of w^site approved by EPA within 24 hours of activity.
13. Pers> taring II--'
Personal airmonito ig shSl^^erformed by the Monitoring Contractor in accordance with
USDOLOSHAreq wents7The person who conducts sampling shall possess a valid NYS
:1^Bl certificate. P< oral air monitoring will be performed on a minimum of one worker per
shift per resideni Pi for the first 6 weeks of cleaning operations. This may be extended
based on a deter ion made by EPA, DEP and OSHA. Thereafter personal air monitoring
samples will by peen at one sample per quadrant per day. All samples shall be collected and
analyzed in accc irdance with NIOSH 7400 Method for PCM and 7402 for TEM. Analysis
gofthese. ^es shall be the responsibility of the Monitoring Contractor. Results of analysis
led to EPA by the laboratory in an approved electronic format within 24 hours of
ion. Copies of the results shall also be sent immediately to DEP, OSHA and the
employer. The employer will make these results available to the employees or then-
designated representatives for their review in accordance with 29 CFR 1910.1020 and 29
CFR 1926.1101.