NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.3
☕ Buy me a coffee
← Document results/Asbestos - BOX 22/No folder label
Document / 215 pages

HVAC consulting services invoice, NYC WTC site, 2003

Machine-extracted title · confidence 95%

Invoice for HVAC consulting services provided at the World Trade Center site in 2003.

NYC-WTC_000135339–000135553
Page image
Scanned page image, NYC-WTC_000135508
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document `~ LW Ventilation System Identification: ----- - ` 3,.r Location: ' I Area Served: m,,, • - ' t ' 38..✓ IkcR 1 ACE l.L fi,t Associated mechanical room: clean_-[Y N thy Y N stored chemicals/refuse Y✓ N System Components Surface Component Dust/ WTC • not present [NOTE: if component not present (NP), not found (NF) or inaccessible (1) please Debris Dust indicate in last column] • not found Present? Present? • Inaccessible Outside air intake: Location:

Accessible for inspection? Y_/N (explain):

— louvers, grates andlor screens Ni' — outside air duct , — outside air damper(s) f.' j Air handling unit: — outside air mixing chamber — filter rack(s) i — filter media — blower assembly ind. blower wheel, blower housing, air vanes, in-line noise attenuators — blower housing acoustical lining h — preheat coils Ni — heating coils — cooling coils — re-heat coils — condensate drain pan I h► — supply air plenum — supply air plenum damper(s) S 1.1P — vibration collars h }' Supply air distribution: —.Supply air ducts Est. total in ft 1# No. locations inspected Specify type (circle). ;metau fbrous lass lined met1 zaasonzy fibrous glass board er uct — Accessible in-line fire dampers Est. total qty No. locations inspected 'F — Accessible turning vanes Est. total qty No. locations inspected — In-line reheat/cooling coils Est. total qty_ . No. locations inspected — Supply air diffusers Est. total qty Z No. locations inspected--J__— Return air distribution: — Return air ducts Est. total in ft No. locations inspected 2 - Specify type (circle): fibrous glass lined metal masonry fibrous glass board flex-duct — Return air plenum Est. total RA plenum areas I No. locations inspected— j_ — Return air plenum damper Est. total qty No. locations inspected — Accessible in-line fire dampers Est. total qty No. locations inspected — Accessible turning vanes Est. total qty No. locations inspected — Return air grilles Ea total qty No. locations inspected J

NYC-WTC 000135508

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000135508Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →