HVAC inspection letter, 380 Rector Place, Jan 2003

Machine-extracted title · confidence 100%

Letter from Athenica Environmental Services reporting HVAC and environmental inspections performed at 380 Rector Place on January 13, 2003.

NYC-WTC_000113862–000113891

Folder label: “380 RECTOR PL 1000544, 16/7505”

Page image
Scanned page image, NYC-WTC_000113890
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.i Central Ventilation System Visual Insnection Form Pa I of l Ventilation System Identification:

Location: Area S ed: _ ~- h~` t: — . 1 ~-.t(~ ~ L~ •` ~L A~ `-~A3'l'-{tN Associated mechanical room: clean ✓Y N dry ✓Y N stored chemicals/refuse Y N Surface Component System Components Dust/ WTC . not present [NOTE: if component not present (NP), not found (NF) or inaccessible (I) please Debris Dust • not found indicate in last column] Present? Present? a inaccessible Outside air intake: Location:

Accessible for inspection? Y v/ N _(explain):

- louvers, grates and/or screens - outside air duct - outside air damper(s) Air handling unit: - outside air mixing chamber - filter rack(s) - filter media ('j - blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators - blower housing acoustical lining - pre-heat coils N - heating coils - cooling coils - re-heat coils 17 - condensate drain pan - supply air plenum r, - supply air plenum damper(s) - vibration collars NF Supply air distribution: - Supply air ducts Est. total In ft. _ Tl No. locations inspected , -3 Specify type (circle): 4nt 1 ,• fibrous glass lined al me r masonry fibrous glass board flex-duct wood — Accessible in-line fire dampers Est. total qty I No. locations inspected_ — Accessible turning vanes Est. total qty No. locations inspected n — In-line reheat/cooling coils Est. total qty No. locations inspected ~ rf — Supply air diffusers Est. total qty No. locations inspected `~ Return air distribution: — Return air ducts Est. total In ft ZO No. locations inspected Specify type (circle): metal fibrous glass lined metal masonry fibrous glass board flex-duct wood — Return air plenum Est. total RA plenum areas 1 No. locations inspected_ — Return air plenum damper Est. total qty _ No. locations inspected — Accessible in-line fire dampers Est. total qty No. locations inspected — Accessible turning vanes Est. total qty No. locations inspected N♦• — Return air grilles Est. total qty No. locations inspected

NYC-WTC-000113890

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000113890Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →