HVAC inspection letter, 380 Rector Place, Jan 2003

Machine-extracted title · confidence 100%

Letter from Athenica Environmental Services reporting HVAC and environmental inspections performed at 380 Rector Place on January 13, 2003.

NYC-WTC_000113862–000113891

Folder label: “380 RECTOR PL 1000544, 16/7505

Page image
Scanned page image, NYC-WTC_000113864
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

380 Rector Place, Manhattan, NY January 30, 2003

Inspection Details:

As part of the survey,.the Mechanical and the Environmental Professionals inspected the following HVAC system types. All identification data and visual inspections are documented in the attached checklists.

A. One (01) laundry exhaust fan located on the main roof, one (01) mechanical exhaust fan in the elevator room, one (01) mechanical exhaust fan in the pump water room, one (01) kitchen and one (01) bathroom exhaust fan, located in the pump water room, on the main roof. Five (05) mechanical kitchen and bathroom exhaust fans located on the 9th floor roof. B. One (01) AC unit located in the elevator room and serves the elevator room. C. One (01) AC unit located on the main roof, and serves the hallways. D. One (01) AC unit located in the ceiling of the lobby area and serves the lobby. E. One (01) AC unit located in the west side of the lobby, and serves west side of the lobby. F. One (01) AC unit located in the east lobby and serves the east side of the lobby. G. One (01) AC unit located in the compactor room and serves the compactor room. H. MV-1 unit located in the basement and serves the basement storage rooms and boiler room. I. HV-2 unit located in the basement and serves the basement corridors.

Summary of Findings:

WTC related dust was found in pit areas of the fresh air intakes of MV-1 and HV-2 systems. WTC related dust was found in the mechanical exhaust fan# (04) which is located on the 9th floor.

Scope of Work:

Cleaning is required to remove WTC related dust from inside the pit areas of the HV-1 and HV-2 systems. Cleaning is required to remove WTC related dust from the mechanical exhaust fan # (04) and its components and associated ducts.

Sincerel\;.

Vasilis Bellos

Director of Operations

Attachments: 1) Ventilation System Evaluation forms

Page 2 of 2

NYC-WTC-000113864

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000113864Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →