HVAC inspection invoice, 380 Rector Place, Jan 2003

Machine-extracted title · confidence 100%

Invoice from Athenica Environmental Services for HVAC and environmental inspections performed at 380 Rector Place on January 13, 2003.

NYC-WTC_000113892–000113951

Folder label: “380 RECTOR PL 1000544, 16/7505

Page image
Scanned page image, NYC-WTC_000113924
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

250 South End Avenue, Manhattan, NY January 30, 2003

Inspection Details:

As part of the survey, the Mechanical and the Environmental Professionals inspected the HVAC system types listed below.

A. A total of five (5) mechanical exhaust fans of kitchens and bathrooms located on the main roof, two (2) mechanical exhaust fans located on the roof of the elevator room, one (1) mechanical exhaust fan located on the roof of the ME room, two (2) mechanical exhaust fans located on the 14th floor, one (1) mechanical exhaust fan located in the basement. B. Two (2) chimneys stacks located on the main roof and two (2) chimneystacks located on the roof of the elevator room (these two (2) stacks were not inspected because the air outlets more than 20 W. in height above the roof level). C. One (1) HVAC unit located on the roof of the elevator room and serving the elevator room D. One (1) AC-2 unit located in the compactor room and serving the lobby. E. One (1) heating unit located in the lobby and serving the east side of the lobby. F. One (1) heating unit located in the lobby and serving the west side of the lobby. G. One (1) 1-IV-1 located in the basement and serving the basement rooms and the hallways on all floors.

Detailed identification data and visual inspections are documented in the attached checklists

Summary of Findings:

HV-1 unit heave accumulation of WTC related dust was observed inside the unit between the air intake grill and the filter. WTC related dust was not observed beyond the filters.

WTC related dust was observed in the mechanical exhaust fans # 03, 04, 05, 06, 07, 08, 09 (as they are numbered in the evaluation forms) in the units and their associated components. Approximately 1,300.00 linear feet of ductwork is covered with WTC related dust and needs to be cleaned.

All the other systems inspected appear to be free of WTC dust. All the findings are documented in the attached evaluation forms.

Scope of Work:

Clean the exhaust fans # 03, 04, 05, 06, 07, 08, 09 located on the main roof, on the roof of the elevator room and on the 14th floor, along with their associated components and ducts. Also clean the entire system of the HV-1 located in the basement.

Please feel free to contact me should you require any further information.

Si cerel~y,,

'Vas Bellos Director of Operations

Attachments Ventilation System Evaluation forms

Page 2 of 2

NYC-WTC-000113924

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000113924Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →