Part IV- Waste Management Plan
133-135 Greenwich Streett21-23 Thames Street
Airtek Project 05-0701 — August 10, 2005
At completion of the Abatement Phase only the wooden framing and
exterior masonry & metal façade materials of the buildings will remain.
The interior materials will have been spray-encapsulated, and the exteriors
will have been low-pressure washed.
The classification of building components and contents will be an ongoing effort and will
be conducted by the Environmental Consultant in accordance with applicable New York
City, New York State and federal laws, rules, and regulations. This Plan is intended as a
working document to be used during ongoing operations at the Site, and will be updated
as necessary as new information becomes available.
3.0 Waste Characterization Background Data
While WTC impact varied to a degree from site to site, results of COPC sampling around
the WTC zone exhibited were more similarity than difference with regard to RCRA
Characteristics.
3.1 Corollary Data —130 Liberty Street
The TRC Preliminary Waste Characterization Study conducted at 130 Liberty
Street, 50 feet from the subject site, indicated the following:
"Fourteen representative composite bulk dust (six samples) and anticipated waste stream/building
material (eight) samples were collected on various floors of the Building and analyzed for
Resource Conservation and Recovery Act (RCRA) Characteristics and full Toxicity Characteristic
Leaching Procedure (TCLP) analysis. Results of the 14 samples were compared to criteria
provided in 40 CFR Part 261 sections 21 through 24 and Environmental Protection Agency
Publication SW 846 Chapter 7. None of the 14 samples collected exceed the criteria provided in
40 CFR Part 261 sections 21 through 23 or SW 846 Chapter 7. None of the eight building material
samples exceeded the Maximum Concentration of Contamination for the Toxicity Characteristics
provided in 40 CFR section 261.24. One of the six composite bulk dust samples, collected in a
mechanical room on the 40th floor, exhibited levels of cadmium that exceeded 40 CFR section
261.24. This sample exceeded the cadmium maximum concentration of 1.0 mg/L with a result of
6.2 mg/L. (Additional sampling will be conducted to determine whether specific equipment or
surface coatings in the 40th Floor mechanical room contributed to the cadmium levels.)."
3.2 Site Data
Although dust available for sampling at the subject site is very limited (WTC
Dust impact was noted only in the kitchen of the second floor of the 133-135
Greenwich Street Building), dust sampling and TCLP analysis was conducted on
one sample composited from samples collected in three areas of the above-
referenced kitchen. Compositing of the samples was required in order to meet the
total mass requirements of the analytical method. There was simply not enough
capturable WTC dust to run three samples.
Results of the sample are pending and will be compared to criteria provided in 40
CFR Part 261 sections 21 through 24 and Environmental Protection Agency
NYC-WTC 000135127