Part II - Environmental Community Monitoring Plan
133-135 Greenwich & 21-23 Thames Streets
Airtek Project 05-0701— Rev 2 September 16, 2005
Table A-1 - Measurement Quality Objectives - Parameter PM10(Dichotomous Sampler)
Requirement Frequency Acceptance Criteria Reference Information/Action
Reporting Units All data µg/m3 40 CFR, Pt 50.7
Filter Checks
Visual defect check Filter All filters See reference Vol II, MS 2.10.4 Discard any defective
Integrity filters
Collection efficiency Purchase 99 % 40 CFR, Pt 50,
Integrity Specification f 5 µg/m3 App M, S 7.2 As measure by DOP test
Alkalinity < 25.0 (ASTM-2988). Reject
Filter Conditioning All filters microequivalents/gram shipment.
Equilibration time " 40 CFR, Pt S0, Following 2 months storage
Temperature range at least 24 hours App M, S 9.3 at ambient temp and
Temperature control 15 to 30° C 4 CFR, Pt 50, App relative humidity.
Humidity range f 3C M, S 7.4 Repeat equilibration
Humidity control 20 to 45 % relative humidity Keep thermometer in
f 5% relative humidity balance room and record
temperature daily.
Keep hygrometer in the
balance room and record
humidity daily.
Equipment
Sampler Purchase specification 40 CFR, Pt 53.9
Purchase
Flow rate transfer specification 40 CFR, Pt 50, App M, S 7.3
standard Purchase
Analytical balance specification 40 CFR, Pt 50, App M, S 7.5
Purchase Vol II, MS 2.10.4
Mass reference standards specification
Vol II MS 2.10.4
Detection Limit The lower limit of the mass
LDL Not applicable Not applicable 40 CFR, Pt 50, concentration is determined
App M, S 3.1 by the
repeatability of filter tare
weights, assuming the
nominal air sample
volume for the sampler.
Sampler Calibration 40 CFR, Pt 50, Adopt new calibration
Flow control device App M, S 7.1 curve if no evidence of
On installation, after <4% difference from Vol II, MS 2.10.2 damage, otherwise replace.
repairs, after out-of- manufacturers spec and
limits flow check actual 40 CFR, Pt 50,
Elapsed time meter App M, S 7.1 Adjust or replace.
On receipt and 1/6
months 115 min 40 CFR, Pt 50,
Flow-rate transfer App M, S 8.2 Checked against NIST-
Standard Periodically traceable primary standard.
f2% over the expected range Vol II, MS 2.10.1
of ambient conditions Vol II, MS 2.10.1
Balance Calibration 1/year Vol II, MS 2.10.4 Calibrate and maintain
according to the
manufacturer's
recommendations.