Part II - Environmental Community Monitoring Plan 133-135 Greenwich & 21-23 Thames Streets Airtek Project 05-0701 - Rev 2 September 16, 2005

4/yr (manual) External Leak Check 4/yr < 80 mL/min not described Internal Leak Check 4/yr < 80 mL/min not described Temperature Audit 4/yr -I- 2C not described not described Pressure Audit 4/yr (?) ±10 mm not described Balance Audit 1/yr Manufacturers specs not described

Precision Collocated samples every 6 days for 25% of sites CV < 10%' Part 58, App.A, Sec Single analyzer 1/3 mo. CV < 10% 3.5/5.5 Single Analyzer 1/yr CV < 10% not described Reporting Qrg. 1/ 3 mo. CV < 10% not described not described

Calibration & Check Standards Flow Rate Transfer Std. 1/yr +2% of NIST-traceable Std. Part 50, App.L Sec 9.1 and 9.2 Field Thermometer 1/yr + 0.1 C resolution not described + 0.5 C accuracy not described Field Barometer 1/yr + 1 mm Hg resolution not described + 5 mm Hg accuracy not described Working Mass Stds. 3-6 mo. 0.025 mg not described Primary Mass Stds. 1/yr 0.025 mg not described

Table A-1 - Measurement Quality Objectives - Parameter PMIO (Dichotomous Sampler) Requirement Frequency Acceptance Criteria Reference Information/Action Reporting Units All data Pg/md 40 CFR, Pt 50.7

Filter Checks Visual defect check Filter All filters See reference Vol II, MS 2.10.4 Discard any defective Integrity filters Collection efficiency Purchase 99% 40 CFR, Pt 50, Integrity Specification + 5 pg/m3 App M, S 7.2 As measure by DOP test Alkalinity <25.0 (ASTM-2988). Reject Filter Conditioning All filters microequivalents/gram shipment. Equilibration time 40 CFR, Pt 50, Following 2 months storage Temperature range at least 24 hours App M, S 9.3 at ambient temp and Temperature control 15 to 30° C 4 CFR, Pt 50, App relative humidity. Humidity range + 3C M, S 7.4 Repeat equilibration Humidity control 20 to 45 % relative humidity Keep thermometer in + 5 % relative humidity balance room and record temperature daily.

Keep hygrometer in the balance room and record humidity daily. Equipment Sampler Purchase specification 40CFR. Pt 53.9 Detection Limit Purchase The lower limit of the mass EDE? rate transfer >j®fci®piti0hle »t^}iPeW, App M. S 7.3 40 CFR, Pt 50, concentration is determined standard Purchase App M, S 3.1 by the Analytical balance specification 40 CFR, Pt 50, App M, S 7.5 repeatability of filter tare Purchase Vol II, MS 2.10.4 weights, assuming the Mass reference standards specification nominal air sample Vol II, MS 2.10.4 volume for the sampler.

36

CITY_DEP_WORBY_CANNATA_SUBP_000087319

NYC-WTC_000425895

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000425895Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000444890

Chain-of-custody/documentation for air monitoring around 133-135 Greenwich and 21-23 Thames

Similar indexed content

Compare copies and versions →