NYC-WTC_000099818
Billing record for asphalt and gravel roof cleanup services performed at 55 Nassau Street in November 2002.
6 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗Correspondence regarding DEP acceptance of a variance package for asbestos removal at 130 Cedar Street.
NYC-WTC_000125698–000125753Folder label: “130 CEDAR STREET”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document 01/11/2005 01:42 17325653654 NOVA DEVELOPMENT GRP PAGE 07
• EAST COAST HAZ MAT REMOVAl, INC Asbeatas Abatement Contractor 494E, 41 Street, Paterson, NJ 07504 Phone: (973) 345.0022 Fax: (973)345-4685
We are requesting a variance from the following ,subsections: Section 1-81(rrt); Partial plasticization of the work area(s). Section 1-82(a) & 1-83(a): Remote decontamination facilities, Section 1-91C~); Static negative air Pressure of less than 0.02 inch water column.
o Procedures a. All tent enclosures and contiguous spaces within a radius of 10 feet shall be roped off and regulated to allow only certified workers and authorized visitors to enter. All tents shalt be lined with 2layers of plastic sheeting (6-mil thickness at a minimum), the amounts of ACM that may be abated in each modified tent shall not exceed 160 square foot, or (b) 2601)near feet, or ( 160 combined feet (square plus linear). b. All modified tents shall be fully framed (including horizontally across the top, it applicable) with 2x3 (Minimum) wood or metal studs spaced not more than 36 inch center- to-center vertically around all sides (except at the entry/exit which shall not exceed 36 inch width); and a minimum of one air volume change per IS minutes through each modified tent 8ha11 be maintained. C. An airlock having at least 3 feet length between the two curtained doorways shall be
J constructed at the entrance to each and every tent if the decontamination unit is not attached to the Lents, and if a decontamination unit is not attached to each tent, located within each airlock there shall ,be extra clean and uncontaminated disposable protective suits. d. Any decontamination unit that 19 not attached to 4 tent (i.e. that is remote from a tent) shall be constructed in compliance with the requirements of Attachment R. Decontamination units that are attached to tents shall comprise at toast a shower room and .a clean room, with one curtained doorway separating them, and with a second curtained doorway separating the tent from the shower room. e. After the ACM removal and bagging, the bagged waste shall be REPA-vacuumed then wet cleaned and transferred into the airlock or into the shower room for double bagging, and thereafter the double-bagged waste shall be transferred outside the clean room for Its final transfer to storage in a holding area and/or to legal means of disposal.
V. Work Area; Fourth throughout Twelve Flood.
1000 SF Variance VA chase 50 LP Variance VA 124 SF Variance VA 100 SF Variance VA 50 LF Variance yA Total 1220SF& 1,00LF. is 200 SF VarianceVA Floor I Chaac N. 100 LF Variance VA Closet 120 SF Variance VA LLath Floor I Fright Tley. Door Sea1iboor Insulation 10Q SF Variartae VA • Fif!h Ploor J,Electrical Closet Wire insulation 100 LP Variance VA
NYC-WTC 000125724
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000099818
Billing record for asphalt and gravel roof cleanup services performed at 55 Nassau Street in November 2002.
6 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
9 shared non-person entities · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
12 shared non-person entities · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123541
Invoice from Asbestos Removal Corp dated August 6, 2002 for roof cleanup services at 29 Broadway.
8 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000100474
Billing statement from a contractor detailing charges for environmental cleanup and facade work.
6 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123194
Invoice for roof asbestos abatement work completed at 198 Broadway covering nearly 25,000 square feet.
6 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000116315
Invoice from Asbestos Removal Corp to NYC DEP detailing costs for roof cleanup at 300 Albany Street.
3 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000128146
Project notification form submitted to DEP regarding asbestos work schedules at 80 Gold Street.
7 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121883
Invoice from Fiber Control Inc. dated September 25, 2002, regarding work at the 116 Chambers Street site.
4 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112570
Invoice detailing costs for asphalt and gravel roof cleanup operations at 63 Wall Street in June 2002.
5 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115082
Permit application submitted by Benjamin Kurzban & Son Inc. to the DEP for roof work at 205 Pearl Street.
6 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000125069
A single-page record labeled for 130 Cedar Street with a unique NYC-WTC identifier.
Filed in the same folder
NYC-WTC_000125070
Contractor requirements and site plan notes for demolition work at 30 Cedar Street.
Filed in the same folder
NYC-WTC_000125073
General notes and requirements for demolition work at 130 Cedar Street including contractor qualifications.
Filed in the same folder
NYC-WTC_000125076
Correspondence submitting updated asbestos project documentation to the DEP for 130 Cedar Street.
Filed in the same folder
NYC-WTC_000125098
Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.
Filed in the same folder