• h. Decontamination units that are attached to tents shall comprise
at least a shower room and a clean room, with one curtained
doorway separating them, and with a second curtained
doorway separating the tent from the shower room.
Remove asbestos containing materials as per the Schedule.
No residue shall remain after the work is completed.
j. After the ACM removal and' bagging, the bagged waste shall
be HEPA-vacuumed then wet cleaned and transferred into the
airlock or into the shower room for double bagging, and
thereafter the double-bagged waste shall be transferred
outside the airlock or outside the clean room for its final
transfer for storage in an enclosed waste container.
k. Upon completion of the abatement, the tent work area shall wet
cleaned by using rags, mops or sponges and be lightly
encapsulated with clear encapsulant to lockdown residual
asbestos.
8.8 Removal: Removal of Asbestos Sash Material shall be performed in
accordance with the following procedures:
1. Personal air monitoring shall be performed in compliance with OSHA
• standards, 29 CFR 1926.58 (f). At least two (2) of the OSHA
representative personal samples collected daily per floor, must
achieve a minimum volume of 560 liters.
2. A NYCDEP-certified asbestos handler supervisor shall be on-site at all
times during the window sash removal process. The supervisor shall
establish and maintain a project log and be responsible for any
emergency situations that may occur.
3. Workers performing the work must receive OSHA awareness training
and work practices training related to asbestos disturbances and
handling or must have a valid NYC DEP asbestos handler certificate.
4. All windows undergoing sash removals shall be regulated to prevent
unauthorized visitors and a curtained doorway shall be established at
the entrance of each work area.
5. All objects must be moved at least 6 feet away from the vicinity of the
windows or covered with I layer of 6-mil plastic.
6. Floor surfaces along the length of the window extending 1 foot on both
sides and 4 feet in front, shall be covered with at least I layer of 6-mil
plastic and shall be used as a staging area.
7. All surfaces of the window to be removed shall be HEPA vacuumed
and wet wiped prior to plasticization of the sash.
Prepared by JLC Environmental Consultants, Inc. Project No. 04-3271 Page 51
NYC-WTC 000125629