EAST.COAST UAZ•MAT REMOVAL,INC
Asbestos Abatement Contractor
494 E.41 Street, Paterson, NJ 07504
Phone:(973)345-0022
Fax (973) 345.4665
Work Area B (Pipe Shaft)
Ground Floor Chase N. Bath Pipe Insulation I 50 LF Variance TM
Second Floor Chase N. Bath Pipe Insulation 50 LF Variance TM
•Third Floor Chase N. Bath Wire Insulation 50 LF Variance TM
Fourth Floor Chase N. Bath Pipe Insulation 50 LF Variance TM
Fifth Floor Chase N. Bath Pipe Insulation 100 LF Variance TM
Sixth Floor Chase N. Bath Pipe Insulation • 50 LF Variance TM
Seventh Floor Chase N. Bath Pipe Insulation 100 LF Variance TM
Eight Floor Chase N. Bath Pipe Insulation 50 LF Variance TM
Ninth Floor Chase N. Bath Pipe Insulation 50 LF Variance TM
Tenth Floor Chase N. Barb Pipe Insulation .50 LF Variance TM
Eleventh Floor Chase N. Bath Pipe Insulation 50 LF Variance TM
Twelve Floor Chase N. Bath Pipe Insulation 50 LF Variance TM
All Floors Pipe Shaft
Ground, Floor Chase N. Bath Total 700 LF •Variance TM
2-12
Abatement of transite panels and fire doors (440 s.f.)
Abatement of wire insulation (116 LF)
Abatement of pipe insulation (Pipe Shaft) (700 LF)
• We shall comply with attachment TM and D.
We are requesting a variance from the following subsections:
Section 1-81(m): Partial plasticization of the work area(s).
Section 1-82(a) & 1-83(a): Remote decontamination facilities.
Section 1-91®: Static
negative air Pressure of less than 0.02 inch water column.
Work Procedures (Work Area: A & B)
a. All tent enclosures and contiguous spaces within a radius of 10 feet shall be roped off and
regulated to allow only certified workers and authorized'visitors to enter.
•All tents shalt be lined with 2 layers of plastic sheeting (6-mil thickness at'a minimum), the
amounts of ACM that may be abated in each modified tent shall not exceed 160 square feet, or (b)
260 linear feet, or 0160 combined feet (square plus linear).
b. All modified tents shall be fully framed (including horizontally across the top, if
applicable) with 2x3 (minimum) wood or metal studs spaced not more than 36 inch center-
to-center vertically around all sides (except at the entry/exit which shall not exceed 36 inch width);
and a minimum of one air volume change per 15 minutes through each modified tent shall be
maintained.
c. An airlock having at least 3 feet length between the two curtained doorways shall be
constructed at the entrance to each and every tent if the decontamination unit is not attached to the
tents, and if a decontamination unit is not attached to each tent, located within each airlock there shall
be extra clean and uncontaminated disposable protective suits.
d. Any decontamination unit that is not attached to a tent (i.e. that is remote from a tent) shall be