Fax:7185953648 Feb 28 2005 17:07 • P.13 NYC DEP ACP

ST. COAST'-°a z - T REMOVAL, INC .. Asbestos Abatement Contractor 494 .E; 41 Street, Paterson, NJ 07504 Phone: (973). 345-0022 Far'(973) 345-4665

e. constructed in compliance with the requirements of Attachment D. Decontamination units that are attached to tents shall comprise at least'a shower room and a•clean room, with one curtained .doorway separating them, and with a second curtained doorway separating the tent from the shower room. After the ACM removal and bagging, the bagged waste shall be HEPAvacuumed then wet cleaned and transferred into the airlock or into the shower room for double. bagging, and thereafter the double-bagged waste shall be transferred outside the clean room for its final transfer to storage in a holding area and/or to legal means of disposal.

Additional Requirements for Work Area: B (Pipe Shaft)

Modified tents shall be constructed at the each entry to pipe shaft. An airlock shall.be constructed at the entrance to every modified lent Remote decontamination unit shall be constructed in the distance of maximum 50 linear feet from every modified tent. Large Personal and Waste . decontamination unit shall be constructed and attached to modified tent at the ground floor level. Minimum of one air volume change per 10 minutes through entire pipe shaft - modified tent shall be maintained. Upon completion of removal, each surface shall be HEPA vacuumed, and then wet-wiped to remove any loose visible debris and coated with a transparent encapsulant. Prior to the completion of each shift, the single disposable bag will be brought over to the waste decon unit (wash room), where the bags shall be wetted down and placed into an additional 6-mil disposable bag. The second disposable will be secured with water resistant duct tape, labeled and brought down to hhe waste container for storage until the completion of work. Upon completion of entire pipe shaft work area and acceptable visual clearance, final air clearance with TEM method shall be perform by independent monitoring company.

throughout Twelve Floors. V. Work Area: Fourththroughout ..r u~

Fourth Floor Entire—North Area Floor Tile Mastic .1000 SF Variance VA Fourth Floor Electrical Closet Transite Panel 120 SF Variance VA Fourth Floor Fright Elev. Door Sealed Door Insulation 100 SF Variance VA Fourth Floor Electrical Closet Wire Insulation 50 LF Variance VA Total 1220 SF & SOL'F Fifth Floor South-East Area Floor Tile/Carpet Mastic 200 SF Variance VA Fifth Floor Electrical Closet Transite Panel 1.20 SF Variance VA Fifth Floor Fri ht Eiev. Door Sealed Door Insulation 100 SF Variance VA Fifth Floor Electrical Closet Wire Insulation 100 LF Variance VA Fifth Floor Entire Ceiling Skim Coat 2,900 SF Variance VA Fifth Floor North-East Pipe Insulation ' 15 LF Variance VA • Total 3320 SF & 115LF Sixth Floor . Entire—North Area Floor Tile.Mastic 2700 SF Variance VA Sixth Floor Electrical Closet Transits Panel - .120.SF Variance VA Sixth Floor Fright Elev. Door Sealed Door Insulation . 100 SF Variance VA Sixth Floor Electrical Closet 1 Wire Insulation .50 LF Variance VA

NYC-WTC 000125088

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125088Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →