EAST COAST I AZ`MAT BE OVAL,94C
/beste Abatement Contractor
494 E 41 Street, Paterson, NJ 07504
Phone: (973) 345-0022
.Fax"• (973) 346-4065
Roof Bulkhead Entire Electrical Wire 1550 LF Full Containment
Roof Bulkhead Machine Room Electrical Panel 500 SF Variance
•Ground Floor Electrical Closet Transite Panel 120 SF Variance
Ground Floor Fright Elev. Door Sealed Door Insulation 100 SF Full Containment
Ground Floor Electrical Closet Wire Insulation 50 LF Full Containment
Ground Floor Entire Skim Coat Ceiling Plastr 5000 SF Full Containment
Total 8177 SF&
5715 LF
Abatement of T ansite Panels, Wall Tar, Interior Door Caulking (1,877 sq. ft.)
We shall comply with Full Containment Procedure with Special Condition.
We are requesting a variance from the following subsections:
Section 1=81(m): Partial plasticization of the work area(s).
Work Procedures
1. We shall comply with all necessary regulation according to full containment procedure except
Partial plasticization of the work areas, where asbestos materials are locate on the wall as.
Transite Panels (Electrical Rooms) —1,240 SF
Interior Door Caulking'— 2 SF
Interior Wall Tar (Pump Room) — 35 SF
Transite Panels (Machine Room) — 500 SF
Sealed Door Insulation —100 SF
2. The walls surfaces not being abated and floor of the work area, shall be plasticized with two
layers of 6-mil plastic sheeting.
3. The numbers of air changes per hour shall be increased to 6.
IV. rd Floor..
Work Area: A. Second and Third
B. All Floors (Ground, Floor Second throughout Twelve)
Work Area: A
Second Floor Electrical Closet Transite Panel 120 SF Variance TM & D
Second Floor Fright Elev. Door Sealed Door Insulation 100 SF Variance TM & D
Second Floor Electrical Closet Wire Insulation 50 LF Variance TM & D
Second Floor East Side Pipe Insulation 16 LF Variance TM & D
Third Floor Electrical Closet Transite Panel 120 SF Variance TM & D
Third. Floor Fright Elev. Door Sealed Door Insulation 100 SF Variance TM & D
Third Floor Electrical Closet Wire Insulation 5012 Variance TM & D
Total 440 SF &
116 LF
5
NYC-WTC 000125086