NYC 9/11 Public Portal Document
130 Cedar Street July 15, 2004
Selective Demolition and Façade Restoration Koenen Associates
"Rejected", with one (1) copy of correct or corrected literature with copy of the
transmittal for the Architect. 0
4. All copies of Manufacturer's literature required to be resubmitted hereunder shall
be original printed material. Reproductions of printed material will not receive
consideration.
D. Submissions of Samples
1. All samples shall be submitted in triplicate unless otherwise indicated in the
Specifications.
2. Samples will receive consideration only when accompanied by the transmittal
form properly filled out, as indicated, and listing each sample, as well as the
listing of any ASTM, Federal or other standard references specified or applicable
and such additional Information as may be required by the Specifications for the
materials being submitted. Any deviation from the contract requirements shall be
so stated on the above form or attached to it.
3. The Architect shall have the right to require submission of samples of any
materials, whether or not specifically Indicated In the various Sections of the
Specifications.
4. Unless otherwise specified, samples of sufficient size to Indicate general visual
effect shall be submitted. Where samples must show a range of color, texture
finish, graining, or other similar property, the Contractor shall submit sets of pairs
illustrating the full scope of the range.
5. One (1) sample of each submission will be returned to the Contractor. Samples
stamped "Revise and Resubmit' or "Rejected" by the Architect shall be
resubmitted in triplicate by the Contractor.
6. All samples stamped "No Exceptions Taken", "Make Corrections Noted", "In
General Conformance With Design Concept" or "In General Conformance With
design Concept Except As Noted" shall be kept at the site In the Contractor's field
office facilities for reference at all times. Revise and Resubmit" or "Rejected"
samples shall not be kept at the site.
2.02 MANUALS
A. Where manuals are required to be submitted covering items included in this work, prepare all
such manuals in durable plastic binders approximately 8-1/2" x 11" In size with at least the
following:
1. Identification on, or readable through, the front cover stating general nature of the
manual.
2. Nearly typewritten Index near the front of the manual furnishing immediate Information as
to location in the manual of all emergency data regarding the installation.
3. Complete Instructions regarding operation and maintenance of all equipment Involved.
4. Complete nomenclature of all replaceable parts, their part numbers, current cost, and
name and address of nearest vendor of parts.
5. Copy of all guarantees and warranties Issued.
•
Submittals ['MI.is'.i,1