130 Cedar Street July 15, 2004 Selective Demolition and Façade Restoration Koenen Associates

17. The Contractor shall submit one copy of each standard referred to in the Specifications (ASTM, Fed. Spec., etc.) with the submission of each respective shop drawing, sample, or literature. •

B. Submission of Shop Drawings

1. Architectural Work: Submit one (1) sepia reproducible and three (3) black line of each shop drawing to the Architect for approval. If approved, the Architect will return one (1) sepia stamped "No Exceptions Taken" or "Make Corrections Noted", and the Contractor shall print the required number of copies. In the event the Architect returns one (1) sepia stamped "Revise and Resubmit' or "Rejected", the Contractor shall make indicated changes and resubmit one (1) sepia reproducible and two (2) black line prints to the Architect.

2. Structural work and Mechanical Work: Submit one (1) sepia reproducible and three (3) black line prints of each shop drawing to the Engineer, with one (1) black line print (for first submission only) and copy of the transmittal to the Architect. If Accepted, the Engineer shall return one (1) sepia stamped "In General Conformance With Design Concept" or "in General Conformance With Design Concept Except As, and the Contractor shall print the required number of copies. In the event the Architect returns one (1 sepia stamped "Revise and Resubmit' or "Rejected", the Contractor shall make indicated changes and resubmit one (1 ) sepia reproducible and two (2) black line prints to the Engineer, with a copy of the Transmittal form to the Architect.

3. Prints: The Contractor shall provide all prints or shop drawings as reasonably required by subcontractors, material suppliers, superintendents, inspectors, and others as required for the work, or as directed by the Architect. The Contractor shall pay all costs in connection with printing and distribution of shop drawings.

C. Submission of Manufacturer's Literature, including Catalog, Catalog Cuts, Brochures, Charts, Test Data and Similar Information

1. Manufacturer's literature will receive consideration only when accompanied by the transmittal form properly filled out, as indicated, and listing each item of literature, as well as the Specification Section and paragraph numbers describing such materials. Any deviations from contract requirements shall be stated on the above form or attached to it.

2. Architectural Work: Submit six (6) copies of Manufacturer's literature to the Architect for acceptance. If accepted, the Architect will return four (4) copies stamped "No Exceptions Taken" or "Make Corrections Noted". In the event the Architect returns the literature stamped "Revise and Resubmit" or "Rejected", he will return two (2) copies only. The Contractor shall resubmit six (6) copies of correct or corrected literature of all submissions stamped "Revise and Resubmit" or "Rejected", with one (1) copy of correct or corrected literature with copy of the transmittal form to the Architect.

3. Structural Work and Mechanical Work: Submit six (6) copies of Manufacturer's literature to the Engineer, with one (1) copy of the literature and copy of the transmittal form to the Architect. If accepted, the Architect will return four (4) copies stamped "In General Conformance With Design Concept" or "In General Conformance With Design Concept Except As Noted". In the event the Architect stamps the literature "Revise and Resubmit' or "Rejected", he will return two (2) copies only. The Contractor shall resubmit six (6) copies of correct or corrected literature to the Engineer for all submissions stamped "Revise and Resubmit" or

Submittals 01300-4

NYC-WTC 000125121

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125121Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →