NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
NYC-WTC_000035072–000035088Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Library Search Compound Report Data File C:\HPCHEM\1\DATA\DEC0401\28678 .D vial: 16 Acq On 5 Dec 2001 3:01 am Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 4 Tricosane Concentration Rank 7 R.T. EstConc Area Relative to ISTD R.T. 30.63 0.94 ug/1 175698 Chrysene-dl2 33.03 Hit# Of 5 Tentative ID MW MolForm CAS# Qua
1 Tricosane 324 C23H48 000638-67-5 94 2 Eicosane 282 C20H42 000112-95-8 91 3 Octadecane 254 C18H38 000593-45-3 91 4 Pentacosane 352 C25H52 000629-99-2 91 Abundance Scan 2787 (30.627 min): 28678.D (-) m/z 57.00 100.00% 57
43 71 5000 85
99 30.20 30.40 30.60 30.80 31.00
mz—> —t ' * .. j. A. 4.113127141155169183 207 l , n ,■ |T. . ‘I . , t, ! 324 , I , . , . | . r, , I , I . . , , . . , I , , 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 i ■''' i''' ' i'' ■11 ■' ■' i''b m/z43.05 65.24% Abundance #73318: Tricosane 43 57
71 5000 —- 1*1 r+ r ,4 —e - । 85 30.20 30.40 30.60 30.80 31.00 m/z71.00 61.98% 99
m/z—> ■ ’111 40 A-mTpmr 60 113127141 183197211225 ____________ 296 80 100 120 140 160 180 200 220 240 260 280 300 320 324 ■ i ■ ■ " i ■ " 11" ■ ■ i •1 •' i1 ■ ■
Abundance #39862: Eicosane 43 57 71 —।----- 30.20 30,40 30.60 30.80 31.00 5000 85 m/z 85.05 41.55%
................................................................ ................. ........................................... 11111 1 mz-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 Abundance #71561: Octadecane 57 30.20 30.40 30.60 30.80 31.00 43 71 m/z 41.05 30.60% 85 5000 -
1' i ■ ■ — 2113127141155....... 224/254........... i M I M r' | . . ! . | I M I | . , J l'| J t , I | I I I I p o , | . . bl | TT I I | I I I I TTTI | | 2400409 4=44 --4-000=44 m/z—> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 30.20 30.40 30.60 30.80 31.00
28678.D GCMS1126.M Thu Dec 06 15:13:40 2001 Page 4
NYC-WTC_000035081
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086949
Laboratory results for sample AD22546 indicating other unknown compounds detected via GC/MS on September 27, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000087326
Laboratory report documenting GC/MS analysis of sample AD22655 conducted on October 11, 2001, identifying unknown compounds.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088429
Laboratory report documenting GC/MS analysis of environmental sample AD23319 conducted on October 15, 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder