NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
NYC-WTC_000035072–000035088Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Library Search Compound Report Data File C:\HPCHEM\1\DATA\DEC0401\28678.D Vial: 16 Acq On 5 Dec 2001 3:01 am Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 3 1-Eicosanol Concentration Rank 8 R.T. EstConc Area Relative to ISTD R.T.
29.68 0.83 ug/1 154706 Chrysene-dl2 33.03 Hit# Of 5 'entative ID MW MolForm CAS# Qual 1 1-Eicos anol 298 C2OH420 000629-96-9 76 2 1-Pentadecanol 228 C15H320 000629-76-5 74 3 Acetic acid, octadecyl ester 312 C20H40O2 000822-23-1 70 4 Phosphonic acid, dioctadecyl ester 587 C36H7503P 019047-85-9 70 Abundance Scan 2684 (29.682 min): 28678.D (-) m/z 43.05 100.00% 43
55 83
_A 5000 69 97 111 125 29.40 29.60 29 80 30.00
miz-> J 11′3 60 +l —119 .......... ............. 80 100 120 140 160 180 200 220 240 260 280 m/Z 83.05 56.60% Abundance #72722:1-Eicosanol 57 83 69 97
5000 111 — A । • .— — 29.40 29.60 29.80 30.00 125 m/z 54.95 53.86% — 139 167 280 1 1 1 1 1 TIT TT-p 1 ' i ’ ' 1 1 i ' ' ‘ ' I ’J ' ' i ' ' ' ’ I M ' • i ' ' ' ' i ' 1 ' • i ' 1 mz-> 40 60 80 100 120 140 160 180 200 220 240 260 280 Abundance #70846:1-Pentadecanol
5000 31 69 83 97 —WA T t-t r rr T 29.40 29.60 29.80 30.00 m/z 57.00 53.77% 56 111
125
1 11 ' 1 TIT TT-p | |............ 182 210 I ‘ 11'I'' « ' I•'''I''''I‘'I'' ' ' I ' ‘ ' I ' -.......... — m/z-> 40 60 80 100 120 140 160 180 200 220 240 260 280 Abundance #73048: Acetic acid, octadecyl ester 43 29.40 29.60 29.80 30.00 m/z 97.05 48.83% 5000 61 83 97
m/z—> ' ' i ' ' 40 60 u 80 111 125 139 224 11 ■' ''i'■■■i' ‘ ■ ■ i ■ ■' ■ i ■ ■ ■ ’ i ' '■'i'■■■PJ 1 ■ i ■' 100 120 140 160 180 200 220 240 260 280 252 AAA..... 4 29.40 29.60 29.80 30.00
28678.D GCMS1126.M Thu Dec 06 15:13:38 2001 Page 3
NYC-WTC_000035080
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000088372
Laboratory report documenting GC/MS analysis of environmental sample AD23271 conducted on October 15, 2001.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088207
Laboratory report documenting GC/MS analysis of sample AD23320 conducted on October 15, 2001.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088853
Laboratory report documenting GC/MS analysis of sample AD23501 conducted on October 19, 2001.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000087731
Laboratory report documenting GC/MS analysis of sample AD22977 conducted on October 10, 2001, identifying unknown compounds.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder