NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
NYC-WTC_000034347–000034365Folder label: “GCMS X 11/21/01 A 11/27 - 11/28/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LSC Area Percent Report
Data File C:\HPCHEM\1\DATA\DEC0401\28471.D Vial: 7 Acq On 4 Dec 2001 6:13 pm Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5 Signal : TIC peak R.T. first max last PK peak peak peak % Of # min scan scan scan TY height area % max. total
1 11.711 721 726 744 rBV 2194911 5258925 72.51% 12.507% 2 15.319 1113 1119 1136 rBV 3159539 6932210 95.58% 16.487% 3 20.588 1686 1693 1710 rBV 3283845 7252497 100.00% 17.249% 4 25.004 2168 2174 2186 rBV2 3001299 6754516 93.13% 16.064% 5 25.151 2186 2190 2198 rVB 29818 88724 1.22% 0.211%
6 29.438 2651 2657 2665 rBV 965647 . 1902672 26.23% 4.525% 7 29.548 2665 2669 2675 rW 111551 241390 3.33% 0.574% 8 29.686 2679 2684 2696 rVB 106299 234827 3.24% 0.558% 9 30.081 2721 2727 2735 rBV 357112 748686 10.32% 1.781% 10 30.632 2781 2787 2794 rBV 114276 232880 3.21% 0.554%
11 31.568 2883 2889 2895 rBV 558834 1198560 16.53% 2.851% 12 31.660 2895 2899 2909 rW 173942 396316 5.46% 0.943% 13 31.797 2909 2914 2922 rVB2 34348 85139 1.17% 0.202% 14 32.660 3002 3008 3015 rBV 131466 286354 3.95% 0.681% 15 33.037 3039 3049 3068 rBV2 2218524 5255371 72.46% 12.499%
16 33.615 3104 3112 3122 rBV 141432 331071 4.56% 0.787% 17 34.533 3206 3212 3221 rBV 92692 221653 3.06% 0.527% 18 35.424 3304 3309 3323 rBV 72096 193941 2.67% 0.461% 19 36.287 3398 3403 3409 rBV 33925 89722 1.24% 0.213% 20 37.131 3487 3495 3516 rBV2 1484484 4341563 59.86% 10.325%
Sum of corrected areas: 42047017
28471.D GCMS1126.M Wed Dec 05 11:27:22 2001
NYC-WTC_000034352
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088346
Laboratory report documenting GC/MS analysis of environmental sample AD23270 conducted on October 15, 2001.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034154
Single page of raw GCMS data or header information from samples tested in late November 2001.
Filed in the same folder
NYC-WTC_000034155
Technical data sheet recording instrument parameters and calibration details for GCMS Method 508 analysis conducted in November 2001.
Filed in the same folder
NYC-WTC_000034156
Instrument sequence log listing calibration standards and sample IDs processed between November 26 and 30, 2001.
Filed in the same folder
NYC-WTC_000034160
Laboratory report of a method blank analysis for sample AD28263 conducted on November 26, 2001.
Filed in the same folder
NYC-WTC_000034168
Laboratory report of GCMS calibration data for sample AD28263 conducted on November 26, 2001.
Filed in the same folder