NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
NYC-WTC_000034311–000034330Folder label: “GCMS X 11/21/01 A 11/27 - 11/28/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LSC Area Percent Report
Data File C:\HPCHEM\l\DATA\DEC0401\28430.D Vial: 12 Acq On 4 Dec 2001 11:06 pm Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5
Signal : TIC peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 11.715 721 727 746 rBV 1873056 4759515 71.61% 11.909% 2 15.313 1113 1119 1137 rBV 3003015 6310422 94.95% 15.789% 3 20.592 1687 1694 1709 rBV 2930282 6646340 100.00% 16.630% 4 25.008 2168 2175 2187 rBV2 2854148 6261054 94.20% 15.666% 5 25.155 2187 2191 2201 rVB 24561 81626 1.23% 0.204%
6 29.442 2652 2658 2665 rBV 960082 2002523 30.13% 5.011% 7 29.552 2665 2670 2679 rVB 111482 231968 3.49% 0.580% 8 29.681 2679 2684 2693 rBV 116448 249815 3.76% 0.625% 9 30.075 2722 2727 2733 rBV 409562 858355 12.91% 2.148% 10 30.626 2782 2787 2799 rBV 108899 226941 3.41% 0.568%
11 31.572 2881 2890 2896 rBV 638241 1337960 20.13% 3.348% 12 31.664 2896 2900 2906 rW 178416 389214 5.86% 0.974% 13 31.792 2910 2914 2930 rVB 40587 119062 1.79% 0.298% 14 32.655 3003 3008 3015 rBV 128255 281800 4.24% 0.705% 15 33.041 3042 3050 3070 rBV2 2077499 4979921 74.93% 12.460%
16 33.316 3074 3080 3096 rVB 82811 224973 3.38% 0.563% 17 33.610 3106 3112 3123 rVB 138026 326672 4.92% 0.817% 18 34.537 3208 3213 3225 rBV 91587 221917 3.34% 0.555% 19 35.428 3304 3310 3322 rBV 70079 186933 2.81% 0.468% 20 36.290 3398 3404 3411 rBV2 34867 100020 1.50% 0.250%
21 37.135 3488 3496 3518 rBV2 1399926 4169307 62.73% 10.432%
Sum of corrected areas: 39966338
28430.D GCMS1126.M Wed Dec 05 08:19:25 2001
NYC-WTC_000034316
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088000
Laboratory report documenting GC/MS analysis of sample AD23124 conducted on October 12, 2001.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034154
Single page of raw GCMS data or header information from samples tested in late November 2001.
Filed in the same folder
NYC-WTC_000034155
Technical data sheet recording instrument parameters and calibration details for GCMS Method 508 analysis conducted in November 2001.
Filed in the same folder
NYC-WTC_000034156
Instrument sequence log listing calibration standards and sample IDs processed between November 26 and 30, 2001.
Filed in the same folder
NYC-WTC_000034160
Laboratory report of a method blank analysis for sample AD28263 conducted on November 26, 2001.
Filed in the same folder
NYC-WTC_000034168
Laboratory report of GCMS calibration data for sample AD28263 conducted on November 26, 2001.
Filed in the same folder