NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
NYC-WTC_000034311–000034330Folder label: “GCMS X 11/21/01 A 11/27 - 11/28/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LSC Area Percent Report
Data File C:\HPCHEM\l\DATA\DEC0401\28430.D Vial: 12 Acq On 4 Dec 2001 11:06 pm Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5
Signal : TIC peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 11.715 721 727 746 rBV 1873056 4759515 71.61% 11.909% 2 15.313 1113 1119 1137 rBV 3003015 6310422 94.95% 15.789% 3 20.592 1687 1694 1709 rBV 2930282 6646340 100.00% 16.630% 4 25.008 2168 2175 2187 rBV2 2854148 6261054 94.20% 15.666% 5 25.155 2187 2191 2201 rVB 24561 81626 1.23% 0.204%
6 29.442 2652 2658 2665 rBV 960082 2002523 30.13% 5.011% 7 29.552 2665 2670 2679 rVB 111482 231968 3.49% 0.580% 8 29.681 2679 2684 2693 rBV 116448 249815 3.76% 0.625% 9 30.075 2722 2727 2733 rBV 409562 858355 12.91% 2.148% 10 30.626 2782 2787 2799 rBV 108899 226941 3.41% 0.568%
11 31.572 2881 2890 2896 rBV 638241 1337960 20.13% 3.348% 12 31.664 2896 2900 2906 rW 178416 389214 5.86% 0.974% 13 31.792 2910 2914 2930 rVB 40587 119062 1.79% 0.298% 14 32.655 3003 3008 3015 rBV 128255 281800 4.24% 0.705% 15 33.041 3042 3050 3070 rBV2 2077499 4979921 74.93% 12.460%
16 33.316 3074 3080 3096 rVB 82811 224973 3.38% 0.563% 17 33.610 3106 3112 3123 rVB 138026 326672 4.92% 0.817% 18 34.537 3208 3213 3225 rBV 91587 221917 3.34% 0.555% 19 35.428 3304 3310 3322 rBV 70079 186933 2.81% 0.468% 20 36.290 3398 3404 3411 rBV2 34867 100020 1.50% 0.250%
21 37.135 3488 3496 3518 rBV2 1399926 4169307 62.73% 10.432%
Sum of corrected areas: 39966338
28430.D GCMS1126.M Wed Dec 05 08:19:25 2001
NYC-WTC_000034316
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088000
Laboratory report documenting GC/MS analysis of sample AD23124 conducted on October 12, 2001.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034154
Single page of raw GCMS data or header information from samples tested in late November 2001.
Filed in the same folder
NYC-WTC_000034155
Technical data sheet recording instrument parameters and calibration details for GCMS Method 508 analysis conducted in November 2001.
Filed in the same folder
NYC-WTC_000034156
Instrument sequence log listing calibration standards and sample IDs processed between November 26 and 30, 2001.
Filed in the same folder
NYC-WTC_000034160
Laboratory report of a method blank analysis for sample AD28263 conducted on November 26, 2001.
Filed in the same folder
NYC-WTC_000034168
Laboratory report of GCMS calibration data for sample AD28263 conducted on November 26, 2001.
Filed in the same folder