NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
NYC-WTC_000035153–000035170Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document LSC Area Percent Report . Data File C: \HPCHEM\ 1 \DATA\DECO 4 01\28663.D Vial: 17 Acq On 5 Dec 2001 3:59 am Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5 Signal : TIC peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 11.715 721 727 745 rBV 1666804 4478442 74.46% 13.392% 2 15.314 1113 1119 1138 rBV 2727075 5782522 96.15% 17.291% 3 20.583 1687 1693 1710 rBV 2721913 6014332 100.00% 17.985% 4 25.008 2168 2175 2187 rBV2 2524296 5522745 91.83% 16.515% 5 25.155 2187 2191 2199 rVB 20221 65216 1.08% 0.195%
6 29.442 2651 2658 2665 rBV 600614 1238831 20.60% 3.704% 7 29.552 2665 2670 2676 rW 100672 206427 3 .43% 0.617% 8 29.681 2679 2684 2694 rW 84120 186953 3.11% 0.559% 9 30.076 2722 2727 2740 rBV 347047 701031 11.66% 2.096% 10 30.626 2781 2787 2799 rBV 94524 195521 3.25% 0.585%
11 31.572 2883 2890 2896 rBV 360405 735609 12.23% 2.200% 12 31.664 2896 2900 2910 rW 146359 327375 5.44% 0.979% 13 31.801 2910 2915 2922 rVB2 26128 64697 1.08% 0.193% 14 32.655 3002 3008 3017 rBV 103082 231745 3.85% 0.693% 15 33.032 3042 3049 3064 rBV2 1627264 3971948 66.04% 11.877%
16 33.610 3104 3112 3123 rBV 107920 259425 4.31% 0.776% 17 34.537 3207 3213 3221 rBV 70110 167738 2.79% 0.502% 18 35.428 3304 3310 3316 rBV 49537 128905 2.14% 0.385% 19 36.281 3398 3403 3414 rBV2 23323 63591 1.06% 0.190% 20 37.126 3488 3495 3515 rBV2 1070047 3098597 51.52% 9.266%
Sum of corrected areas: 33441650
28663.D GCMS1126.M Thu Dec 06 15:31:16 2001
NYC-WTC_000035157
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088346
Laboratory report documenting GC/MS analysis of environmental sample AD23270 conducted on October 15, 2001.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder