NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09520 analyzed in May 2002.
NYC-WTC_000023363–000023371Folder label: “GCMS X 5/8/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Data File C:\HPCHEM\1\DATA\MAY0 302\9520.D Vial: 21 Acq On 4 May 2002 9:41 am Operator: Sample GC/MS SCAN 4/22 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P Quant Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 1 2-Pentanone, 4-hydroxy-4-methy Concentration Rank 1
R.T. EstConc Area Relative to ISTD R.T.
8.17 93.62 ug/1 6613800 1,4-Dichlorobenzene-d4 12.19
Hit# of 5 Tentative ID MW MolForm CAS# Qual
1 2 - Pentanone , 4 - hydroxy- 4 -methyl - 116 C6H1202 000123-42-2 64 2 CH2=CHCH2C(O)OCH3 100 C5H802 003724-55-8 10 3 5-Hexen- 2-one 98 C6H10O 000109-49-9 7 4 Acetone________ 58 C3H60 000067-64-1 7 Abundance Scan 341 (8.167 min): 9520. D (-) m/z 43.05 100.00%! 43
5000 59 -------- 101 7.80 8.00 8.20 8.40 8.60
m/z-> 0- ..................... 10 20 30 37 1 40 50 +53+ 60 69 77 83 ' i ' 1 1 ■ i ' 1 ■ ■ i 70 80 ■ i ■ ' ' 1 i ' 1 ' 1 I ' ■ ■ ' i 1 ‘ 90 | 100 110 120 116 m/z 59.05 42.41% Abundance #64274:2-Pentanone, 4-hydroxy-4-methyl- 43
5000 - 59 7.80 8.00 8.20 8.40 8.60 m/z 58.10 16.40%| 27 । 101
miz-> 10 20 I I 30 T 40 +49 50 I 60 ' I ' ■ ■ ■ i 1 ■ ■ ' i
70 80 83 , I ■ i 1 ■ ■ 1 i ■ ■ 1 ■ i ■ ■ ' ■ i ■ '
90 100 110 120 Abundance #1448: CH2=CHCH2C(O)OCH3 43 ............. 1 .................... 7.80 8 00 8.20 8.40 8.60 5000 m/z 101.15 13.50%|
58 3744 ■ । I 72 100 •I । ■ ■ • ■ । I ■ ■ • i ■ ■ ■ ■ । ■ ■ ■ > | i i । ■ ■ । < । > mfe-> 10 20 30 40 50 60 70 80 90 100 110 120 Abundance #63205:5-Hexen-2-one ......... / 43 7 80 8.00 8.20 8.40 8.60 m/z 41.10 6.85%
5000
55 15 27 83 98 p1.......1........ . TT ■ i ■ ■ ■ 1 11711 1‘‘ TIPmmme m/z—> 10 20 30 40 50 60 70 80 90 100 110 120 7.80 8.00 8.20 8.40 8.60
9520.D GCMS0501.M Tue May 07 09:38:43 2002 Page 1
NYC-WTC_000023368
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023122
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023148
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023345
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09518 analyzed in May 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023076
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023327
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09578 analyzed in May 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043678
Calibration table for GC/MS analysis listing deuterated standards and their response values from April 24, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043726
Calibration data for GC/MS analysis of surrogate compounds including dichlorobenzenes and naphthalene from April 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043112
Laboratory report for DEP Box 25 showing GCMS analysis of sample AE09395 with unknown compounds and surrogate data from May 9, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013146
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044621
Calibration scan report for EPA Method 625 showing retention times and deviations for deuterated standards on April 25 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000023148
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043844
Laboratory report for sample AE09681 showing surrogate recovery and unknown compounds from May 17, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043146
Laboratory document displaying a GCMS calibration table with retention times and response factors for deuterated standards from May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043853
Laboratory report for sample AE08016 showing unknown compounds and surrogate data from May 17, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023372
Laboratory report showing GC/MS analysis results for sample AE09446 including surrogate recovery data on May 16, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023255
Laboratory report documenting the detection of unknown compounds and surrogate recovery in sample AE08271 on May 16, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022961
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022962
Fragmentary record containing a document identifier and date from the DEP GCMS analysis series.
Filed in the same folder
NYC-WTC_000022965
Laboratory report of a GCMS blank run conducted on May 14, 2002, showing non-detect results for various compounds.
Filed in the same folder
NYC-WTC_000022990
Laboratory report documenting GCMS calibration verification analysis conducted on May 14, 2002.
Filed in the same folder
NYC-WTC_000022994
Laboratory report of GCMS reference standard analysis conducted on May 14, 2002, showing recovery percentages.
Filed in the same folder